Download Print this page

Master Bilt BEL-2-30 Specification Sheet page 3

Bem/bel series endless remote glass door merchandisers with bottom mounted coil

Advertisement

MODULES REQUIRED FOR 24" WIDE DOOR LINEUPS & BTU PERFORMANCE DATA
MODULES REQUIRED
NO. OF
3
4
5
DOORS
DOOR
DOOR
DOOR
3
1
4
1
5
1
6
7
1
1
8
2
9
1
1
10
2
11
1
12
13
2
1
14
2
15
3
16
4
17
1
18
19
1
3
20
4
21
1
22
1
23
1
24
25
5
MODULES REQUIRED FOR 30" WIDE DOOR LINEUPS & BTU PERFORMANCE DATA
MODULES REQUIRED
NO. OF
2
3
4
DOORS
DOOR
DOOR
DOOR
2
1
3
1
4
1
5
6
2
7
1
8
1
9
1
10
11
2
12
1
13
1
14
1
15
16
2
17
1
18
1
19
1
20
21
2
22
1
23
1
24
1
25
TOTAL OVERALL
+20°F SUCTION MIN.
LENGTH
BTUs (75°F STORE,
6
WITH ONE PAIR
55% RH, +35°F AVER-
DOOR
OF 2" ENDS
AGE PRODUCT TEMP.)
76
/
"
3
8
100
/
"
1
8
123
/
"
7
8
1
147
/
"
5
8
172
/
"
1
2
196
/
"
1
4
220"
243
/
"
3
4
1
267
/
"
1
2
2
291
/
"
1
4
316
/
"
1
8
1
339
/
"
7
8
363
/
"
5
8
388
/
"
1
2
2
411
/
"
1
8
3
434
/
"
7
8
459
/
"
3
4
483
/
"
1
2
3
507
/
"
1
4
3
531"
3
554
/
"
3
4
4
578
/
"
1
2
603
/
"
3
8
TOTAL OVERALL
+20°F SUCTION MIN.
LENGTH
BTUs (75°F STORE,
5
WITH ONE PAIR
55% RH, +35°F AVER-
DOOR
OF 2" ENDS
AGE PRODUCT TEMP.)
66"
96
/
"
1
2
126
/
"
7
8
1
157
/
"
3
8
189"
1
219
/
"
3
8
1
249
/
"
7
8
1
280
/
"
1
4
2
310
/
"
3
4
1
342
/
"
3
8
2
372
/
"
3
4
2
403
/
"
1
4
2
433
/
"
5
8
3
464
/
"
1
8
2
495
/
"
3
4
3
526
/
"
1
8
3
556
/
"
5
8
3
587"
4
617
/
"
1
2
3
649
/
"
1
8
4
679
/
"
1
2
4
710"
4
740
/
"
3
8
5
770
7
/
"
8
-11°F SUCTION MIN.
BTUs (75°F STORE,
55% RH, -3°F AVERAGE
PRODUCT TEMP.)
3750
4750
4600
6150
5750
7625
6900
9150
8050
10,675
9200
12,200
10,350
13,725
11,500
15,250
12,650
16,775
13,800
18,300
14,950
19,825
16,100
21,350
17,250
22,875
18,400
24,400
19,550
25,925
20,700
27,450
21,850
28,975
23,000
30,500
24,150
32,025
25,300
33,550
26,450
35,075
27,600
36,600
28,750
38,125
-11°F SUCTION MIN.
BTUs (75°F STORE,
55% RH, -3°F AVERAGE
PRODUCT TEMP.)
2800
3300
3750
4750
4600
6150
5750
7625
6900
9150
8050
10,675
9200
12,200
10,350
13,725
11,500
15,250
12,650
16,775
13,800
18,300
14,950
19,825
16,100
21,350
17,250
22,875
18,400
24,400
19,550
25,925
20,700
27,450
21,850
28,975
23,000
30,500
24,150
32,025
25,300
33,550
26,450
35,075
27,600
36,600
28,750
38,125
3
-18°F SUCTION MIN.
BTUs (75°F STORE,
55% RH, -12°F AVER-
AGE PRODUCT TEMP.)
5125
6550
8300
9960
11,620
13,280
14,940
16,600
18,260
19,920
21,580
23,240
24,900
26,560
28,220
29,880
31,540
33,200
34,860
36,520
38,180
39,840
41,500
-18°F SUCTION MIN.
BTUs (75°F STORE,
55% RH, -12°F AVER-
AGE PRODUCT TEMP.)
3550
5125
6550
8300
9960
11,620
13,280
14,940
16,600
18,260
19,920
21,580
23,240
24,900
26,560
28,220
29,880
31,540
33,200
34,860
36,520
38,180
39,840
41,500