Download Print this page

Pad Assembly - Fujitsu ScanPartner 15C Consumable Replacement And Cleaning Instructions

Hide thumbs Also See for ScanPartner 15C:

Advertisement

ScanPartner 15C, 600C & 620C C
4
R
ONSUMABLE
EPLACEMENT AND
R
P
A
EPLACING THE
AD
A defective or improperly installed Pad Assembly can cause miss picks,
skew, or double fed documents. To replace the Pad Assembly perform
the following steps.
Remove all the
documents from the
ADF Paper Chute.
Open the ADF by
pressing the ADF
button.
Remove the ADF Pad
Assembly by pressing
the two knobs on the
top of the Pad
Assembly and sliding it
out to remove it.
Attach the new Pad
Assembly by pressing
the two knobs on the
top of the Pad
Assembly and sliding it
down into the slots to
lock it in place.
C
I
LEANING
NSTRUCTIONS
SSEMBLY
ADF Button
Left
Guide
Balance
Wire
Document
Right
Guide

Pad Assembly

Pick and
Feed
Rollers

Advertisement

loading

This manual is also suitable for:

Scanpartner 620cScanpartner 600c