Servicing Information - Panasonic CS-MA90KE Service Manual

Multi-split air conditioners
Table of Contents

Advertisement

Servicing Information

• Remote Control Reset
When the batteries are inserted for the first time, or
the batteries are replaced, all the indications will
blink and the remote control might not work.
If this happens, remove the back cover of the remote
control and you will find a resetting terminal, and by
shorting it with a minus screwdriver, it will return to
normal.
• Changing the wireless remote control transmis-
sion code
When two indoor units are installed in the same
room, in order to prevent operating errors caused by
using two remote controls, set up the remote control
[B ↔ A] switch (SW1).
The unit is set to A when it is shipped.
By adding a jumper wire to the remote control side and a carbon resistor (1/4 W, 10 k
circuit board, it is possible to select 4 types of transmission codes including one at time of delivery condition
(1).
Remote control
Switch SW B ↔ A
1
A
2
B
3
A
4
B
J – B
Switch SW1
Jumper wire
Jumper wire
– 40 –
Remote Control
Indoor printed circuit board
RX
A
B
A
10kΩ
B
10kΩ
CS-MA90KE
Reset terminal
SW1
A
B
SW1
Remote Controller
B
A
B
A
Switch
) to the indoor printed
Note
At product delivery

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs-ma120keCu-ma180keCu-ma240keCs-ma70keCu-ma190ke

Table of Contents