Sony DCR-SR190E Service Manual page 10

Digital video camera recorder
Hide thumbs Also See for DCR-SR190E:
Table of Contents

Advertisement

1-2-3. Self-diagnosis Code Table
Self-diagnosis Code
Block
Detailed
Function
Code
C
0
4
0
0
C
1
3
0
1
C
1
3
0
2
C
3
2
6
0
E
2
0
0
0
E
3
1
0
0
E
6
1
1
0
E
6
1
1
1
E
6
2
0
0
E
6
2
0
1
E
6
2
0
2
E
6
2
0
3
6
2
1
0
E
E
6
2
1
1
E
6
2
1
2
E
6
2
2
0
E
9
1
0
1
E
9
4
0
0
Note 1: Perform adjustment by referring to "STEADY HALL Adjustment" in Service Manual, ADJ. After the adjustment, be sure
to perform "GYRO Sensor Sensitivity Adjustment".
Note 2: When the lens block was replaced, execute the necessary adjustment items referring to Service Manual, ADJ.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the
handheld operation.
DCR-SR190E/SR200/SR200C/SR200E/SR290E/SR300/SR300C/SR300E_L2
Symptom/State
Non-standard battery is used.
"Memory Stick Duo" is unformatted.
"Memory Stick Duo" is broken.
Disc access error
Difficult to adjust focus
(Cannot initialize focus)
EEPROM data are rewritten.
Drive fault
Zoom operations fault
(Cannot initialize zoom lens.)
The abnormalities in initialization of
the focus lens and the abnormalities in
initialization of the zoom lens occurred
simultaneously.
Handshake correction function does not
work well. (With PITCH angular
velocity sensor output stopped.)
Handshake correction function does not
work well. (With YAW angular velocity
sensor output stopped.)
Abnormality of IC for steadyshot.
IC for steadyshot and micro controller
communication abnormality among.
Shift lens initializing failure.
Shift lens overheating (Pitch).
Shift lens overheating (Yaw).
Abnormality of thermistor.
Abnormality when flash is being charged.
Fault of writing to or erasing the
flashmemory
Use the InfoLITHIUM battery.
Format the "Memory Stick Duo".
Insert a new "Memory Stick Duo".
Remove the power source. Reconnect it again and operate your
camcorder again
Retry turn the power on by the power switch. If it does not
recover, check the focus MR sensor of lens block (pin qh, qk of
CN5302 on the VC-492 board: SR290E/SR300/SR300C/
SR300E, pin qd, qg of CN5303 on the VC-492 board: SR190E/
SR200/SR200C/SR200E). If it is OK, check the focus motor
drive IC (IC5404 on the VC-492 board).
Make EEPROM data correct value.
Inspect or replacement of the hard disk drive.
Inspect the lens block zoom MR sensor (pin qh, qk of CN5303
on the VC-492 board: SR190E/SR200/SR200C/SR200E, pin w;,
wa of CN5302 on the VC-492 board: SR290E/SR300/SR300C/
SR300E) when zooming is performed when the zoom lever is
operated, and the zoom motor drive circuit (IC5404 on the VC-
492 board) when zooming is not performed.
Check both C: 32: 60 and E: 61: 10 of the self-diagnosis code.
Inspect PITCH angular velocity sensors (SE8202 on the CM-076
board: SR190E/SR200/SR200C/SR200E, SE7202 on the CM-
077 board: SR290E/SR300/SR300C/SR300E) peripheral circuits.
Inspect YAW angular velocity sensors (SE8201 on the CM-076
board: SR190E/SR200/SR200C/SR200E, SE7201 on the CM-
077 board: SR290E/SR300/SR300C/SR300E) peripheral circuits.
Refer to [1-3-1. E : 62 : 02 (Abnormality of IC for Steadyshot)
Occurred] (SR290E/SR300/SR300C/SR300E only).
Inspect the steadyshot circuit (IC5703 on the VC-492 board)
(SR290E/SR300/SR300C/SR300E only).
SR290E/SR300/SR300C/SR300E only:
1. Inspect the EEPROM (IC1804 on the VC-492).
2. Perform the STEADY HALL adjustment. (Note 1)
3. Replace the lens block. (Note 2)
Refer to [1-3-2. E : 62 : 11 (Shift Lens Overheating (Pitch))
Occurred] (SR290E/SR300/SR300C/SR300E only).
Refer to [1-3-3. E : 62 : 12 (Shift Lens Overheating (Yaw))
Occurred] (SR290E/SR300/SR300C/SR300E only).
Refer to [1-3-4. E : 62 : 20 (Abnormality of Thermistor)
Occurred] (SR290E/SR300/SR300C/SR300E only).
Checking of flash unit or replacement of flash unit.
Inspect the flash memory (IC2201 on the VC-492 board).
1-2
ENGLISH
ENGLISH
Correction
JAPANESE
JAPANESE

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents