Amount Of Hot Water - Noritz N-0841MC Owner's Manual

Condensing tankless gas water heater
Hide thumbs Also See for N-0841MC:
Table of Contents

Advertisement

Troubleshooting-2
(Continued)
The water is not hot enough.
The water is cold when only a
single fixture is open.
Fluctuations in hot water
temperatures.
Setting temperature cannot rise.
The amount of hot water at a
certain fixture is not constant.
The amount of hot water in the tub
is less/more than the set amount.
The flow meter alarm does not
sound even when filled to the set
amount.
Amount of hot water available
has decreased over time.
24
• Are the gas and water supply valves fully open?
• Is the water temperature setting appropriate?
• If the amount of hot water required is very high, it is
possible for the temperature to be lower than the temp-
erature set on the remote controller.
Decrease the amount of hot water passing through the unit
and the temperature should stabilize.
• The unit will not heat the water if the flow rate is less than
0.5 gallons per minute.
Open the fixture more or open other fixtures so that a greater
flow passes through the unit, and the unit should begin
heating again.
• Set water temperature at 115°F to 120°F. This will allow you
to use a higher flow of hot water thus meeting the minimum
flow requirement of 0.5 gpm.
• Clean the water filter of any debris (
• Is the maximum temperature setting appropriate? (

Amount of Hot Water

• When hot water is demanded at other fixtures, the amount
available may be reduced. The maximum flow available
from this unit is 8.4 GPM at a 45°F temperature rise.
• Pressure fluctuations and other plumbing conditions can
cause the temperature and pressure at a fixture to be
unstable, but it should stabilize after a short time.
• There are some types of hot water taps that discharges large
volumes of hot water at first but stabilize after time.
• To keep the temperature stable, the heater limits the
amount of water that can flow through it to a small amount
initially, but the amount increases over time.
• When hot water is used for other fixtures while filling the
bath tub, the tub will not fill as much.
• If there is water in the tub already, or when filling is stopped
and restarted, the tub will fill more.
• The flow meter alarm is set to sound when hot water
is continuously discharged for the set volume of water.
If mixing valves are used, or if cold water is mixed with hot
water at the fixture, the tub will fill more than the setting
of the flow meter alarm.
• Is the water filter clogged? (
(
p.12 and p.13)
p.22)
p.22)
p.17)