VI. Installation instructions
3.Installation of Unit:
3-1.How to select installing location:
3-1-1. How to select installing location for indoor unit
Air inlet/ air outlet should be far away from obstacles, ensuring that air flow must not be kept back;
Do not install the unit at a spot with direct sunshine;
Select a spot convenient for removal of condensed water and easy connection to outdoor unit;
The distance between the spot and TV set or acoustic equipment should be 1m at least;
Keep away from fluorescent lamps or incandescent lamps; (otherwise, it is possible that the wireless remote
controller cannot not be normally utilized to controlled)
Select a solid wall which can bear weight of machine body, free of increase of operating noises or vibration;
Maximum height difference between indoor unit and outdoor unit should be 5m.
3-1-2. How to select installing location for outdoor unit
The installing location can bear weight of machine body, free of strong vibration.
Select a spot with good ventilation, less dust, free of rainwater and direct sunshine
Select a spot from which the operating noise and exhausted hot air can not affect the neighbors;
There should be no obstacles around the outdoor unit, which keep back inlet air/outlet air for the unit;
Select a spot free of leakage of inflammable gases or erosive gases;
L1
L4
L2
3-2.How to fix the mounting plate
Find a structural member of a wall (e.g. column etc.), and fix the mounting plate onto it horizontally.
5K/7K/9K/12K series
Tie the rope at central hole
Mounting plate
Note:
1. To avoid microshock of mounting plate, the hole pointed at by solid arrow must be secured.
2. If expansion bolt is adopted, it is required to adopt slotted holes 11*20or 11*26 with interval of over 450mm
to fix the mounting plate
Dimension
Model
5K/7K
09K
L3
12K
18K
21K
24K
Above 30mm
Align the rope to
the symbol
Plumb bob
Tie the rope at central hole
Mounting plate
Installation & Maintenance Manual
L1
L2
L3
278
368
600
600
368
278
780
500
280
780
500
280
850
500
310
850
500
310
18K ,21K ,24K series
Above 60mm
Align the rope to
Plumb bob
19
Unit: mm
L4
235
235
250
250
290
290
the symbol