Pride Mobility Jazzy 1170 XL Owner's Manual page 44

Hide thumbs Also See for Jazzy 1170 XL:
Table of Contents

Advertisement

Off-board Charger/Programming Socket
You may use an off-board charger to charge the power chair batteries through the 3-pin socket located on
the front of the Europa. If you use an off-board charger, the charger current should not exceed 8 amps.
Contact your authorized Pride Provider for more information.
NOTE: The socket may also be used for reprogramming the Europa. Contact your authorized Pride
Provider for more information.
Sleep Mode (If Enabled)
The power chair controller features a sleep mode. Sleep mode is a built-in circuit that will automatically
shut off the main power if the joystick is not moved in any direction for a period of time. This time factor
is programmed into the controller. To restore power and continue, push and key on the keypad.
Europa Error Codes
The system status light is displayed within the on/off key. This light is lit if the system is turned on. It also
flashes in groups called trouble codes, to indicate system faults. The table below identifies the individual
trouble codes. If your keypad displays one of these codes, contact your authorized Pride Provider.
TROUBLE CODE
SEQUENCE
•—•—•—
••—••—••—
•••—•••—
••••—••••—
•••••—•••••—
••••••—••••••—
•••••••—•••••••—
•••••••—•••••••—
•••••••—•••••••—
•••••••—•••••••—
•••••••—•••••••—
•••••••—•••••••—
NOTE: You must turn the controller off and then on again to reset the controller, even if the source of
the fault is removed/corrected.
In the event of a fault, the system status light displays diagnostic indications. Faults are encoded as follows:
one (for a low battery voltage fault) to twelve (module mismatch) and are displayed by the light flashing the
number of times prescribed by the fault code. The flash sequence (one to twelve) is followed by a long off
period (2 seconds). If more than one fault exists, then the fault having the highest priority is indicated. The
controller must be turned off and then on again even if the source of the fault is removed. If you cannot
resolve the problem, contact your authorized Pride Provider.
44
V I I .
O P E R A T I O N
DIAGNOSIS
DX module fault
DX accessory fault
Left motor (or connection) fault
Right motor (or connection) fault
Left park brake fault
Right park brake fault
Low battery fault
Over voltage fault
CANL fault
CANA fault
Stall timeout
Module mismatch
www.pridemobility.com
SOLUTION
See your authorized Pride Provider.
See your authorized Pride Provider.
Check left motor wiring.
Check right motor wiring.
Check motor/brake wiring.
Check motor/brake wiring.
Check that the battery wiring is secure.
Check that the battery wiring is secure.
See your authorized Pride Provider.
See your authorized Pride Provider.
Turn unit on, then off.
See your authorized Pride Provider.