For ESPLXD-ET technical assistance contact Rain Bird at 800 RAINBIRD (1-800-724-6247) U.S. and Canada or visit us on the web at www.rainbird.com For ETC Manager Cartridge technical assistance contact the ET Manager Hotline at 1-877-351-6588 or visit us on the web at www.rainbird.com/etmanager...
Station Setup ...................26 Fill Out Programming Guide ............10 Flow Sensors Setup ................28 Apply Decoder Address Labels ..........11 Set Up Rain Bird Flow Sensor ............28 Storing the Programming Guide ..........11 Set Up Custom Flow Sensor ............29 Remote Programming ................11 Set Watering Start Times ..........31 Programming Checklist ..............12...
Page 4
Ping Station or MV Decoder ............56 Weather Information ................91 Interpreting Ping Results ............56 Ping Sensor Decoder ..............57 Weather Sensor Status ................58 Master Valve Status ................59 ET Manager Alert Messages ...........60 Landscape Condition Issues ..........63 ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 2 7/16/2012 3:48:01 PM...
Page 5
Set Hours Mode .................. 142 Signal Kc ..................116 NOMV Cycling ..................143 Clear Data .................. 118 Set Historical ET ................120 Weather Interrupts ................122 Manual Watering ............124 Backup and Recall Programs ........124 ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 3 7/16/2012 3:48:01 PM...
Page 6
Section G - Auxiliary Operation ....... 167 Introduction to Flow .............145 Module Status ..............167 FloZones Overview................ 145 Smart Module Status ................ 167 ESPLXD-ET Flow Management Features......... 145 Check Station Module(s) ............167 Clear Programs .............168 FloManager Overview ............. 145 FloWatch Overview ..............
Section A - Introduction & Overview Controller Features The ESPLXD-ET controller has a variety of advanced features to help Welcome to Rain Bird you manage water efficiently, including: l Flow, power, and priority management Thank you for purchasing your new state-of-the-art Rain l 2-Wire and controller-based diagnostics Bird ESPLXD-ET controller.
Controls, Switches and Indicators Display Displays time of day during normal operation; shows commands Key operational features of the ESPLXD-ET Controller front panel: during programming; shows active station and remaining run Programming Dial time during watering Used for programming and to turn the controller on and off.
The ET Manager Cartridge manages watering by changing the Seasonal l Seasonal Adjust percentages are automatically adjusted according Adjust percentage value that is set in the ESPLXD-ET Controller. This to current weather conditions to efficiently manage water use. increases or decreases the programmed watering run times for each l Weather Interrupts based on current rainfall, temperature, and station.
WaterSense® Certification The ESPLXD-ET Controller is certified by the EPA as a product that conserves water. WaterSense is a partnership program sponsored by the U.S. Environmental Protection Agency (EPA) that labels products proven to conserve water. All WaterSense labeled products are independently certified to meet the EPA’s water efficiency and performance criteria.
Indication Activity None (dark) No Power Upper light Blinking Power is present – communication between ESPLXD-ET Controller and ET Manager Cartridge is absent. Lower light Blinking Power is present – communication between the controller and ET Manager Cartridge is absent.
AWG cable is 1.65 miles (2.66 Km). The ESPLXD-ET utilizes a 2-Wire electrical path, upon which decoders NOTE: The ESPLXD-ET controller has 8 connections for up to four can be attached at any location. This allows greater design flexibility separate 2-Wire paths.
Local Sensor Cartridge (PBC-LXD). See Section E for more details. The ESPLXD-ET controller can also interface to a local sensor, such as a rain shutoff device. The local weather sensor connects directly to the ESP-LXD-M50 module via a separate wired or wireless connection rather than through a Sensor Decoder connected to the 2-Wire path.
Valves (Stations) The ESPLXD-ET lets you set a delay between stations. For example, if you set a one minute delay, station 1 will run until finished, followed Valves (or stations) operate at times as specified by irrigation programs. by a one minute delay. Then station 2 will run, followed by another one The controller sends signals to the appropriate decoder, powering minute delay, and so on.
Irrigation Controller Definitions the Programming Guide instructions for more details. Programs Locate the Programming Guide that came with the ESPLXD-ET The process of telling the controller exactly when and for how long controller. you want to water. The controller opens and closes the remote control valves according to a program you set.
Apply Decoder Address Labels Remote Programming The ESPLXD-ET controller can be programmed while operating under Follow the instructions to apply station, master valve, flow and battery power. weather sensor decoder address labels in the appropriate fields on the Programming Guide.
Programming Checklist Set Up Programs (Optional) Set seasonal adjust ............. Page 67 When programming the ESPLXD-ET controller for the first time, it is recommended that you complete the following steps in order. Create a water window ............. Page 72 For your convenience a check-off box is provided for each step.
Turn the controller dial to AUTO. To cancel a currently running program, turn the controller dial to OFF for three seconds and then return the dial to AUTO. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 13 7/16/2012 3:48:06 PM...
Next button if necessary, to advance to the next page. NOTE: Take the appropriate action to address each alarm condition. When all alarms have been addressed, the alarm light on the front panel will no longer be illuminated. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 14 7/16/2012 3:48:07 PM...
Resetting the Controller Use a pen or pencil to depress the RESET button. Sometimes you may want to reset (or reboot) the ESPLXD-ET controller. The “Rain Bird” screen appears, confirming reset. Using the controller’s reset feature does not change or delete the programs you have loaded into the controller.
ET Manager Receiver. NOTE: Resetting the ET Manager Cartridge does not affect internally stored data such as event logs, WRSP signal provider codes or other settings. RESET BUTTON ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 16 7/16/2012 3:48:07 PM...
Optional Features Station Expansion Module (ESP-LXD-SM75) The ESPLXD-ET controller comes standard with 50 stations available. This can easily be expanded by adding one or two optional ESP-LXD- SM75 Station Modules. Each station module adds 75 additional stations to increase capacity to 125 or 200 stations.
NOTE: Be sure to set the hour correctly to either AM or PM. l Press and HOLD buttons to accelerate settings for hours and minutes. Press the + and – buttons to set the current minute; then press Next. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 19 7/16/2012 3:48:08 PM...
Select Program Up to five different valve types are supported by ESPLXD-ET, set up as On the controller front panel, slide the Program Select switch V1, V2, V3, V4, and V5.
Page 29
NOTE: The default quantity of solenoids is 1, however some Guide for future reference. decoders can control 2 solenoids. Press the + and – buttons to see the models of Rain Bird valves which the ESPLXD-ET supports. Select your valve type (if present); then press Next.
The Master Valve Setup screen appears. Press the + and – buttons to enter the desired MV number; then press Next. The ESPLXD-ET supports up to 5 Master Valves or pumps. Each MV must be connected to a Field Decoder and set up in the controller. Both Normally Open master valves (NOMVs) and Normally Closed master valves (NCMVs) are supported.
Page 31
The Shared MVs screen shows the other MVs associated with the selected FloZone. Repeat this process to set up additional master valves. Be sure to note each MV on your Programming Guide for future reference. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 23 7/16/2012 3:48:09 PM...
The Weather Sensor Setup screen appears. Press the + and – buttons to enter the desired weather sensor number; then press Weather sensors are not required for the ESPLXD-ET controller, but they Next. increase functionality by allowing you to prevent or pause irrigation based on changing weather conditions.
The Setup Wizards screen appears. Press the Down Arrow button to select Station Setup then press Next. The Station Setup Wizard tells the ESPLXD-ET controller how many and what type of stations are used by your irrigation system. The Station Setup screen appears. Press the + and – buttons to enter the desired station number;...
Page 35
Repeat this process to set up additional stations. NOTE: If you have already set up your MVs and FloZones, the MV assignments for the currently selected FloZone will be shown in the bottom portion of the screen. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 27 7/16/2012 3:48:10 PM...
MVs or stations if flow rates exceed set thresholds. The ESPLXD-ET can support up to five flow sensors. Press the + and – buttons to select the Rain Bird flow sensor model Set Up Rain Bird Flow Sensor that you’re using.
Next. then press Next. Press the + and – buttons to set the flow sensor Offset, pressing Next and Back to navigate between the number setting fields; then press Next. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 29 7/16/2012 3:48:11 PM...
Page 38
The Master Valve and FloZone assigned to the flow sensor is displayed. Press Next. Repeat this process to set up additional custom flow sensors. Be sure to note each flow sensor on your Programming Guide for future reference. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 30 7/16/2012 3:48:11 PM...
Station Run Time into smaller cycle times. If you plan to use Cycle+Soak, only a single Watering Start Time is required for each program. See Section D, Cycle+Soak for more details. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 31 7/16/2012 3:48:12 PM...
NOTE: If the desired program is not selected, use the Program The ESPLXD-ET controller can be programmed to irrigate on different Select switch to change it. See Section B, Program Select Switch days, dates and cycles. Regardless of which Watering Cycle you set, the for more details.
Turn the controller dial to Set Station Run Times. Change the Program Select switch and repeat this process to set up additional Station Run Times for other programs as desired. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 33 7/16/2012 3:48:12 PM...
(available for purchase) that uses your personal l The Rain Bird ET Manager Scheduler software program uses the computer to simplify ET Manager programming. This application allows capabilities of your sprinkler system and actual site conditions...
Site Assessment Worksheet will help guide you through the ET Manager Scheduling Software. NOTE: The ET Manager Cartridge will not automatically compensate for irrigation design errors or faulty sprinkler equipment. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 35 7/16/2012 3:48:13 PM...
Schedule Report and should be used as a reference when creating a Schedule Report. Use the information from your Site Assessment Worksheet to fill in the Schedule Report tabs. From the ET Manager Scheduler home screen, select “New Schedule ETC-LX”. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 36 7/16/2012 3:48:13 PM...
Page 45
NOTE: As each tab is completed, a new tab is created at the top of the page for future reference. REPEAT Step 2 for each new tab until all tabs are complete. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 37 7/16/2012 3:48:13 PM...
Page 46
Once you have completed all the tabs, a summary tab will be created. Save the Schedule Report to your computer. You can create a different schedule for as many irrigation sites as you need, and retrieve any file in the future to add or update the schedule. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 38 7/16/2012 3:48:13 PM...
Page 47
NOTE: If you have purchased the ET Manager Programming Software, the summary from the Scheduler Software can be sent directly to the ET Manager Cartridge through your computer. Refer to the ET Manager Programming Software Operation Guide located on the Resource CD for more information. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 39 7/16/2012 3:48:14 PM...
“Historical”, in the event of a power outage, or as backup to paging signal interference. The ET Manager CAN be used with historical data only – instead of receiving data from a weather station. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 40 7/16/2012 3:48:14 PM...
NOTE: It is important to keep all run times for a valve on one Program. For example, do not turn on Valve 1 in both Programs A and B. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 41 7/16/2012 3:48:14 PM...
Review and confirm scheduled irrigation Programs, Program Run Times and Station Run Times. Confirm Programs The ESPLXD-ET controller can make calculations and provide feedback on Start Times and total Run Times for programs and stations. Program Summary Review program information for all programs: Turn the controller dial to Test All stations/Check System.
The Confirm Programs screen appears. Press the Down Arrow The Run Times review screen appears with run times for each button to select Review Program; then press Next. station displayed. Press Next. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 44 7/16/2012 3:48:16 PM...
Page 53
Press Next. stations that use sensor override displayed. Press Next. The Calendar Day Off review screen appears with all selected calendar days off displayed. Press Next. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 45 7/16/2012 3:48:16 PM...
Page 54
Press Next. The Backup Programs review screen appears with the Contractor Default backup program status displayed. Press Next. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 46 7/16/2012 3:48:16 PM...
Change the Program Select switch and repeat this process to button to select Program Run Time; then press Next. review and confirm Program Run Times for other programs as desired. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 47 7/16/2012 3:48:17 PM...
The System Diagnostics screen appears with Confirm Programs Cycle+Soak for more details. selected; press Next. The Confirm Programs screen appears. Press the Down Arrow button to select Station Run Time; then press Next. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 48 7/16/2012 3:48:17 PM...
Once Run is pressed, stations can be monitored and advanced by turning the dial to the AUTO position and using the Adv button. Press the + and – buttons to increase or decrease Run Time minutes for the current station. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 49 7/16/2012 3:48:17 PM...
2-Wire Path Diagnostics Short Finding The ESPLXD-ET controller can quickly determine if shorts are present Although finding the exact location of issues in the field often requires on the two-wire path. some amount of in-the-field troubleshooting with a clamp meter, the controller has some built-in features to help you narrow down the Turn the controller dial to Test All stations/Check System.
Page 59
Once repairs are finished, be sure to return to the controller and turn the dial to exit short finding mode. Irrigation can not occur until short finding mode has been cancelled. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 51 7/16/2012 3:48:18 PM...
Decoder Test A confirmation screen appears; press Start. The ESPLXD-ET controller may be able to provide specific information A second confirmation screen appears to confirm the Decoder on particular decoders. Test is In Progress. Turn the controller dial to Test All stations/Check System.
** Multiple address station decoders include the FD-202, FD-401 & FD-601 decoders button to select 2-Wire Diagnostics; then press Next. The 2-Wire Diagnostics screen appears. Press the Down Arrow button to select Line Survey; then press Next. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 54 7/16/2012 3:48:19 PM...
2-Wire path are typically to blame. However, a Not OK Current flag can also be due to one or more misconfigured decoders, and a Not OK Overload flag can be caused by a dead short. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 55 7/16/2012 3:48:19 PM...
The Ping Decoder screen appears with Station Decoder selected. Press Next to ping a Station decoder (or else press the Down The ESPLXD-ET controller can provide detailed information on a Arrow button to select MV Decoder); then press Next. specific decoder.
The System Diagnostics screen appears. Press the Down Arrow button to select 2-Wire Diagnostics; then press Next. The 2-Wire Diagnostics screen appears. Press the Down Arrow button to select Ping Decoders; then press Next. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 57 7/16/2012 3:48:20 PM...
The System Diagnostics screen appears. Press the Down Arrow alarm light will not illuminate. button to select Wthr Sensor Status; then press Next. The Weather Sensor Status screen appears, showing installed weather sensors and their current status. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 58 7/16/2012 3:48:20 PM...
The System Diagnostics screen appears. Press the Down Arrow button to select Wthr Sensor Status; then press Next. The MV Status screen appears, showing installed master valves and their current status. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 59 7/16/2012 3:48:20 PM...
ETM™/IQ or ETM™/IQ /PBC position. From the Moisture Levels screen, press the Alrt button to view the Alert Message and press CLEAR. If the problem persists, the Alert will return. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 60 7/16/2012 3:48:20 PM...
Page 69
A Remote Mounting Kit may be needed to improve radio There are 4 reasons the Weather Signal Accuracy reception. Contact your Rain Bird Distributor to find out more information may be low: about an optional Remote Mounting Kit (ETM – RMK). Turn the dial to the ETM™/IQ...
Page 70
ET Manager Cartridge. If the problem persists, the ET Manager Cartridge Reset is experiencing radio initialization problems, this Receiver must be replaced. Contact your Rain Bird Distributor. message will appear. Radio Failure Your ET Manager Cartridge uses a radio to receive The radio may need to be re-initialized.
Manually water the station if it is too dry to get it the water it needs. Adjust the run time using small intervals of time, 1 or 2 minutes. This will help determine what run time is optimal to prevent dry or wet stations. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 63 7/16/2012 3:48:21 PM...
Page 72
To water the next cycle you may manually start the program(s), or adjust cycle sprinklers should water the next watering cycle. the Moisture Levels for the selected program(s) to 0 (see the Moisture Levels section). ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 64 7/16/2012 3:48:21 PM...
Page 73
Moisture Level(s). Change the Saturation Allowance to a lower amount to decrease the amount of rainfall that can accumulate in the Moisture Level(s). ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 65 7/16/2012 3:48:21 PM...
Page 74
1 Hour Rain Interrupt setting. Program a 24 Hour Rain Interrupt to cancel watering until rain accumulations reach below the programmed 24 Hour Rain Interrupt setting. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 66 7/16/2012 3:48:21 PM...
Section D - Advanced Programming Adjust Individual Program Turn the controller dial to Seasonal Adjust %. The ESPLXD-ET controller has a wide variety of advanced but easy-to-use features designed to simplify irrigation. Seasonal Adjust % The ET Manager Cartridge manages watering by changing the Seasonal Adjust percentage value.
The Seasonal Adjust by Month screen appears with % Adjust selected; press Next. NOTE: The % Adjust will automatically change to the new month’s percentage setting on the first day of the month. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 68 7/16/2012 3:48:23 PM...
The Seasonal Adjust screen appears. Press the Down Arrow button to select By Month; then press Next. The Seasonal Adjust by Month screen appears. Press the Down Arrow button to select Select PGMs; then press Next. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 69 7/16/2012 3:48:23 PM...
Rain Delay calculates and displays automatically. The ESPLXD-ET can also be equipped with an optional Rain Bird ET Manager Cartridge to automatically calculate and automate rain shutdown. Ask your Rain Bird distributor for more details or visit the Rain Bird web site, www.rainbird.com.
The Calendar Day off screen appears, showing (up to 5) scheduled calendar days off in chronological order. Unprogrammed days will The ESPLXD-ET controller can be programmed to suspend irrigation on show as Unused. a particular calendar date, up to 5 different days of the year.
To set another program, change the Program Select switch to the desired program; a confirmation appears. Repeat this process to set or clear Water Windows for other programs as desired. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 72 7/16/2012 3:48:24 PM...
Watering Cycles Custom, Odd, Odd no 31st, Even The process for setting up Custom, Odd, Odd no 31st, and Even The ESPLXD-ET controller supports a variety of flexible Watering Cycles is very similar. watering day cycle options. Turn the controller dial to Watering Cycles.
Page 82
Watering Cycles for other programs as desired. NOTE: Watering day selections carry over to Watering Days dial positions and vice-versa. See Section B, Select Days to Water for more details. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 74 7/16/2012 3:48:24 PM...
Cyclical Watering for other programs as desired. NOTE: Watering day selections carry over to Watering Days dial positions and vice-versa. See Section B, Select Days to Water for more details. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 75 7/16/2012 3:48:25 PM...
Station Settings Set Up Cycle+Soak The ESPLXD-ET controller Cycle+Soak feature allows water to be applied to stations intermittently and without creating complex programs. It can apply to any station and is useful for locations such as hillsides which can be difficult to irrigate effectively.
The Station Settings screen appears. Press the Down Arrow button to select Station Delay; then press Next. The ESPLXD-ET controller can be programmed to include a delay between stations. This feature delays the start of the next sequential The Delay Between stations screen appears. Press the + and station in a program after the previous station completes.
The Station Settings screen appears. Press the Down Arrow button to select SimulStations; then press Next. To prevent the ESPLXD-ET controller from irrigating too many stations simultaneously, you can set the maximum number of stations per The Station Settings screen appears with PGM SimulStations program that are allowed to run.
Set SimulStations for Controller The ESPLXD-ET Maximum Number of SimulStations screen appears. Press the + and – buttons to set the maximum number of NOTE: The LXD SimulStations settings will supersede program- irrigation stations (from 1 to 8) that can operate simultaneously;...
Station Sequencing Turn the controller dial to Station Settings. The ESPLXD-ET offers advanced programming features to optimize water windows. The Station Sequencing option allows you to select from two methods of station sequencing for program operation: l Sequence by Station Number (system default).
The ET Manager shows irrigation status, keeps irrigation logs for each program, and provides system settings to customize cartridge operation. When the ESPLXD-ET Controller dial is set to the ETM (or ETM /PBC ) Setting position, the display and soft-keys are controlled by the ET Manager Cartridge.
The ET Manager Cartridge will use the Moisture Level to set the Seasonal Adjust percentage in the ESPLXD-ET Controller. The current Moisture Level and Total Irrigation Amount screen for Program A appears. Press Next to view the next program’s NOTE: Moisture Levels is the default home screen for the ETM Moisture Level.
ET Manager Cartridge. The weather signal contains the most recent weather conditions including: solar energy, temperature, wind, humidity, and rainfall. Turn the controller dial to ETM (or ETM /PBC Settings; then press Menu. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 84 7/16/2012 3:48:27 PM...
Page 93
Signal Provider with the ET Manager Receiver serial number, which can be found on the label attached to the receiver/antenna). Once activated the ET Manager Receiver will begin receiving hourly weather data. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 85 7/16/2012 3:48:28 PM...
Turn the controller dial to ETM (or ETM /PBC Settings; then press Menu. The ET screen appears. Press Next to view rainfall amounts. The Rain screen appears. Press Next to view Seasonal Adjust percentages. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 86 7/16/2012 3:48:28 PM...
The PGM A Irrigation Log appears. Press Next to view the next Turn the controller dial to ETM (or ETM /PBC program’s Irrigation Log. Settings; then press Menu. To clear the log, press Clear. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 88 7/16/2012 3:48:29 PM...
Page 97
The log will reset the Last date to None, Days Watered and Total Water to 0.00, and the Since date to the current date. Press Next to view the next program’s Irrigation Log. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 89 7/16/2012 3:48:29 PM...
5 interrupt events that have occurred, including the type, date and time it started, and when the interrupt cleared. When the ET Manager issues a weather interrupt, the alarm light on the ESPLXD-ET controller is illuminated. Turn the controller dial to ETM...
“Low” are the high and low values since 12:00 AM that day. The ET Manager screen appears. Press the 2 button to select Logs. The Logs screen appears. Press the 3 button to select Weather Information. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 91 7/16/2012 3:48:30 PM...
Times section in the Appendix. The Irrigation Amount screen appears. Press Edit to manually Turn the controller dial to ETM (or ETM /PBC adjust the amount for Program A. Settings; then press Menu. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 92 7/16/2012 3:48:30 PM...
Page 101
0.00 is displayed, then pressing the - button one more time to display “Non ET”. The Irrigation Amount screen appears. Press Next to view and edit the Irrigation Amount for Programs B, C and D ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 93 7/16/2012 3:48:30 PM...
Settings; then press Menu. The ET Manager screen appears. Press the 3 button to select Settings. The ET Manager Settings screen appears. Press the 1 button to select Irrigation Control. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 94 7/16/2012 3:48:31 PM...
If the watering run time is set to 10 minutes, a Minimum Run Time limit of 80% means the shortest possible run time would be 8 minutes. A Maximum Run Time limit of 120% means the longest possible run time would be 12 minutes. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 96 7/16/2012 3:48:31 PM...
Page 105
NOTE: To follow best water management practices of deep, less frequent watering, set the percentage at or above 80%. The Maximum Run Time % screen appears. Press the + and - buttons to set the desired percentage. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 97 7/16/2012 3:48:31 PM...
Weather Reach Signal Provider (WRSP) that closely represents the location of the ESPLXD-ET Controller and irrigation site. The System Settings screen appears. Press the 1 button to select NOTE: To find your Weather Region number, refer to the ET Data Source.
Page 107
The Weather Region screen appears. Press the + and - buttons to enter the Weather Region number. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 99 7/16/2012 3:48:32 PM...
The ET Manager can accept actual rainfall input from both 1mm/tip (ETM – RG) and 0.01”/tip (RAINGAUGE) rain gauges. These two gauges connect to the ESPLXD-ET controller in the same way. See the Rain Gauge Installation section for more information.
Page 109
The Rain Source screen appears. Press the + and - buttons until Weather Signal is selected. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 101 7/16/2012 3:48:33 PM...
Press the + and - buttons to select your type of rain gauge, “ETM- Settings. RG” or “0.01” / Tip” . The ET Manager Settings screen appears. Press the 2 button to select System Settings. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 102 7/16/2012 3:48:33 PM...
The ET Manager screen appears. Press the 3 button to select Press the + or - to select the Rain Region number for your area. Settings. The ET Manager Settings screen appears. Press the 2 button to select System Settings. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 103 7/16/2012 3:48:34 PM...
Settings; then press Menu. The System Setting screen appears. Press the 1 button to select Data Source. The Data Source screen appears. Press the 3 button to select Signal Provider Code. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 104 7/16/2012 3:48:34 PM...
Page 113
Press the + and - buttons to enter the value for A; then press Next to move to the next letter. When the value for every letter is entered, press Done. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 105 7/16/2012 3:48:34 PM...
Saturation Allowance settings can be made for each individual program (depending on plant type) and are typically programmed as half the total irrigation amount. Turn the controller dial to ETM (or ETM /PBC Settings; then press Menu. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 106 7/16/2012 3:48:35 PM...
Page 115
Maximum Hourly Rain setting; then press Next. The Saturation Allowance for PGM A appears. Press the + and - buttons to adjust the setting; then press Next to view and adjust the next program. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 107 7/16/2012 3:48:35 PM...
The System Setting screen appears. Press the 2 button to select Turn the controller dial to ETM (or ETM /PBC Control Settings. Settings; then press Menu. The Control Settings screen appears. Press the 2 button to select ET Settings. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 108 7/16/2012 3:48:35 PM...
Page 117
NOTE: When the ET Manager Cartridge is set to Historical, “H-ET” will be displayed in the upper right corner of the Moisture Levels screen as a reminder that the ET Manager is set to Historical ET. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 109 7/16/2012 3:48:36 PM...
The ET Manager screen appears. Press the 3 button to select Settings. The ET Manager Settings screen appears. Press the 2 button to select System Settings. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 110 7/16/2012 3:48:36 PM...
Settings; then press Menu. The System Setting screen appears. Press the 2 button to select Control Settings. The Control Settings screen appears. Press the 2 button to select ET Settings. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 112 7/16/2012 3:48:37 PM...
Page 121
The ET Settings screen appears. Press the 3 button to select Wind Adjustment. The Wind Adjustment screen appears. Press the + and - buttons to set the desired percentage. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 113 7/16/2012 3:48:37 PM...
The Units screen appears. Press the + and - buttons to select English or Metric. The ET Manager screen appears. Press the 3 button to select Settings. The ET Manager Settings screen appears. Press the 2 button to select System Settings. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 114 7/16/2012 3:48:37 PM...
/PBC Settings; then press Menu. The System Setting screen appears. Press the 2 button to select Control Settings. The Control Settings screen appears. Press the 3 button to select Options. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 116 7/16/2012 3:48:38 PM...
Page 125
The Options screen appears. Press the 2 button to select Signal The Signal Kc screen appears. Press the + and - buttons to select Use or Ignore. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 117 7/16/2012 3:48:38 PM...
/PBC Settings; then press Menu. The System Setting screen appears. Press the 2 button to select Control Settings. The Control Settings screen appears. Press the 3 button to select Options. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 118 7/16/2012 3:48:38 PM...
Page 127
A “Clearing Data, Please Wait” message appears while the data is cleared. Once the data has cleared, “Data Cleared” is displayed. NOTE: Clearing data will NOT make an Alert Message clear. See the Alert Messages section for more details. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 119 7/16/2012 3:48:39 PM...
Historical ET average for January; then press Next to move to the next month. When the ET average for every month is entered, press Done. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 120 7/16/2012 3:48:39 PM...
NOTE: Once the default settings have been changed, they are Turn the controller dial to ETM (or ETM /PBC not able to be automatically reset by the ESPLXD-ET Controller. Settings; then press Menu. Rain Interrupt If rainfall over the last hour exceeds the 1 Hour Rain Interrupt setting, watering is canceled.
Page 131
The next watering cycle will start when the moisture level has depleted enough to require an irrigation. This may take several days. The Weather Interrupts screen appears. Press the 2 button to select Temperature. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 123 7/16/2012 3:48:40 PM...
NOTE: The ESPLXD-ET Controller will backup and recall programs to 100%. Prior to the next scheduled start time, the ET Manager will for both the ESPLXD-ET Controller AND the ET Manager Cartridge. change the Seasonal Adjust percentage back to the proper adjusted value to reflect the current Moisture Level.
Backup and Recall Programs The Backup Programs screen appears with Store Programs selected; press Next. The ESPLXD-ET controller comes standard with a simple to use backup programs feature. Backup Programs allows you to save your programs as Contractor Default and then recall them at a later time. It also includes a Delayed Recall feature that lets you save a normal irrigation schedule as the Backup and then restore it later automatically.
The Special Features screen appears. Press the Down Arrow button to select Backup Programs; then press Next. The Backup Programs screen appears. Press the Down Arrow button to select Recall Programs; then press Next. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 126 7/16/2012 3:48:41 PM...
The Special Features screen appears. Press the Down Arrow button to select Backup Programs; then press Next. The Backup Programs screen appears. Press the Down Arrow button to select Delayed Recall; then press Next. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 127 7/16/2012 3:48:41 PM...
An optional Programming Backup Cartridge (PBC-LXD) is available Connector Cable for use with a barcode scanning pen. If you do not for the ESPLXD-ET controller which allows you to create and Restore plan to use the barcode scanning feature right away then store the multiple Backups of irrigation programs.
Disconnect the ET Manager Cartridge ribbon cable from the knife- edge connector located at the top-left corner inside the cartridge bay of the controller front panel. Set the ET Manager Cartridge safely aside. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 129 7/16/2012 3:48:42 PM...
Page 138
PBC-LXD. controller front panel. NOTE: There may be a short delay while the ESPLXD-ET controller recognizes the newly installed cartridge for the first time. NOTE: The PBC-LXD can be operated only in a controller connected to power.
(Backup01 through Backup08). The names cannot be changed but the date and time stamp update automatically whenever a particular file is used. Unused files display as <Unused>. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 131 7/16/2012 3:48:43 PM...
The PBC Restore screen appears. Press the + or – buttons to choose a Restore file; then press Next. NOTE: Available files display a creation date and time stamp. Unused files display as <Unused> and are not available for Restore. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 132 7/16/2012 3:48:43 PM...
Disconnect the PBC-LXD cartridge ribbon cable from the knife- edge connector located at the top-left corner inside the cartridge bay of the controller front panel. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 133 7/16/2012 3:48:43 PM...
Backup Cartridge (PBC-LXD) that lets you set up Field Decoder addresses in the ESPLXD-ET controller by using a barcode scanning pen to read the removable barcode labels attached to Rain Bird’s field decoders (see Programming Guide instructions for more details).
Page 143
Disconnect the Receiver/Antenna Cable’s RJ45 connector from the ET Manager Cartridge. Connect the PBC-LXD ribbon cable to the knife-edge connector located at the top-left corner inside the cartridge bay of the controller front panel. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 135 7/16/2012 3:48:44 PM...
Page 144
PBC-LXD Connector cable’s serial connector (9 pin swing the PBC-LXD up into place, snapping the top-latch. male). Route the PBC-LXD RJ45 Connector Cable through the cable channel on the back of the controller front panel. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 136 7/16/2012 3:48:44 PM...
Rain Bird recommends using a Unitech MS100-2 barcode pen with 9 pin (female) serial connector. Go to www.ute. com for more details. Locate the Programming Guide that came with the ESPLXD-ET controller. Then scan Setup Barcode # 2 and again you’ll hear audible beep(s) to confirm that the second scan was successful.
Test Barcode Scanning Pen The PBC Main Menu appears. Press the Down Arrow button to select Test Barcode Pen; then press Next. Locate the Programming Guide that came with the ESPLXD-ET The PBC Test Barcode Pen screen appears with instructions. controller.
Test Barcode Scanning Pen process before starting as the test process will not update or replace your decoder addresses. Locate the Programming Guide that came with the ESPLXD-ET controller. The PBC Main Menu appears. Press the Down Arrow button to select station Setup;...
Page 148
To scan master valve, flow sensor or weather sensor decoders; from the Scan When Ready screen, press the Type button to select the desired device. Then repeat the scanning process as previously described. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 140 7/16/2012 3:48:46 PM...
Disconnect the PBC-LXD cartridge ribbon cable from the knife- edge connector located at the top-left corner inside the cartridge bay of the controller front panel. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 141 7/16/2012 3:48:46 PM...
Special Features Set Hours Mode You can set the ESPLXD-ET controller to display time in one of three Set Language hours modes; Auto, AM/PM or 24 Hour. You can set the ESPLXD-ET controller to one of six supported languages; Turn the controller dial to Special Features.
(NCMVs) open, so they are not included in the selection screen. NCMVs will show as - and can not be changed. Once you advance past the last MV, you will be returned to the Special Features screen. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 143 7/16/2012 3:48:47 PM...
The ESPLXD-ET controller flow features can be divided into two different Introduction to Flow functional groups; FloManager and FloWatch. FloManager...
Press the + and – buttons to select the desired pipe size measurement (English or metric). To use FloManager or FloWatch with the ESPLXD-ET controller, you first need to set the measurement units for flow management. Turn the controller dial to Special Features.
FloManager ON will automatically change the setting to Station Priorities. Press Accept to make the change or else press Reject. See Section D, Advanced Programming, Station Sequencing for more details. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 147 7/16/2012 3:48:48 PM...
Next. The Flow Smart Module PGM screen appears with Set Flow Rates selected; press Next. Repeat this process to manually set up Flow Rates for additional stations as desired. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 148 7/16/2012 3:48:48 PM...
2) to select the desired FloZone number; then press - (button entered information; if flow sensors are present it will rely on Learned Flow information, which is typically more accurate. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 149 7/16/2012 3:48:49 PM...
FloWatch Set Up and Use FloWatch The ESPLXD-ET controller lets you set the flow rates you expect or FloWatch unleashes the true power of the ESPLXD-ET controller. to automatically Learn Flow rates based on real usage. Once flow is FloWatch compares current flow conditions to expected learned...
This will allow FloWatch to react selected; press Next. appropriately to the SEEF and SELF settings. The Flow Smart Module PGM screen appears. Use the Down Arrow to select FloWatch; then press Next. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 151 7/16/2012 3:48:49 PM...
(from 1-10 minutes) that a flow rate must remain at (or above) the threshold before the controller will issue an alarm or take action. Press the + and – buttons to set the Settling Time; then press Next. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 152 7/16/2012 3:48:49 PM...
Page 161
Press the + and – buttons to set the SEEF Action; then press Next. Cycle+Soak station runtimes. A SEEF or SELF condition can not be detected if the SEEF and SELF settling times are equal to or longer than station cycle times. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 153 7/16/2012 3:48:49 PM...
Page 162
Next. activated. You may also wish to temporarily disable FloWatch l Press and HOLD buttons to accelerate settings for hours and occasionally, such as when normal maintenance is occurring. minutes. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 154 7/16/2012 3:48:50 PM...
24 hours. The Flow Smart Module PGM screen appears with Set Flow Rates A confirmation screen appears; press Next again to set the Learn selected; press Next. Flow exercise. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 155 7/16/2012 3:48:50 PM...
The Flow Smart Module PGM screen appears with Set Flow Rates your flow metering hardware and flow sensor. Low flow readings selected; press Next. can be caused by faulty flow meters or flow sensors. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 156 7/16/2012 3:48:50 PM...
Page 165
Learn Flow operation will start. NOTE: Station or FloZone flow rates can still be entered manually. See Set Flow Rates Manually in the FloWatch section. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 157 7/16/2012 3:48:51 PM...
The Smart Module Status screen appears with Flow Smart Module selected; press Next. The Flow Module Status screen appears. Press the Down Arrow button to select View Flow Rates; then press Next. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 161 7/16/2012 3:48:52 PM...
The Smart Module Status screen appears with Flow Smart Module selected; press Next. The Flow Module Status screen appears. Press the Down Arrow button to select View Flow Rates; then press Next. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 162 7/16/2012 3:48:52 PM...
The confirmation screen appears; press Yes to clear the logs. selected; press Next. The Flow Module Status screen appears. Press the Down Arrow button to select View flow Logs; then press Next. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 163 7/16/2012 3:48:52 PM...
The Smart Module Status screen appears with Flow Smart Module selected; press Next. The Flow Module Status screen appears. Press the Down Arrow button to select View Current flow; then press Next. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 164 7/16/2012 3:48:53 PM...
Module Status The LXD Station Modules screen appears showing all recognized modules. Press Back to return to the previous screen or press Next Confirm that your ESPLXD-ET controller recognizes installed to review flow and Weather Sensors. Station Modules. The standard ESP-LXD-M50 module will use two of the four available slots.
The Clear Programs screen appears with Individual Program selected; press Next. The ESPLXD-ET controller allows you to clear an individual A confirmation screen appears. To clear the selected Program, Program, all of your Programs or Restore the controller to it’s press and hold down the Yes button for four seconds.
All Programs; then press Next. A confirmation screen appears. To Clear All Programs, press and hold down the Yes button for four seconds. If you’re not sure, press No. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 169 7/16/2012 3:48:54 PM...
Restore Defaults A confirmation screen appears. Restore the ESPLXD-ET controller’s factory default settings. Turn the controller dial to Clear Programs. CAUTION: Be very careful about using the Restore Defaults option as all previous settings, including decoder addresses, will be permanently cleared from system memory. Consider using the Clear All Programs option instead so that your decoder addresses will not be erased.
Manual Watering Start Station Manually The ESPLXD-ET controller allows you to manually start a station, a NOTE: Manual Watering > Start Station will pause currently program, or to open a Normally Closed Master Valve (NCMV) to provide running programs. water to a FloZone for manual watering.
Page 180
AUTO position. You can use the Adv button to advance to the next station and the + and – buttons to increase or decrease the Run Time of the current station. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 172 7/16/2012 3:48:55 PM...
Program or else press Back to cancel. NOTE: If the desired Program is not selected, use the Program Select switch to change it. See Program Selection in Section A for more details. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 173 7/16/2012 3:48:55 PM...
NOTE: To clear a previously set MV Water Window, press the + and – buttons to set both the Open and Close times to OFF (between 11:59 and 12:00 AM). ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 174 7/16/2012 3:48:55 PM...
Page 183
Yes button to include the selected MV in the Water Window or press No to exclude it. Press the Next and Back buttons to navigate through the days of the week and repeat the selection process as desired. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 175 7/16/2012 3:48:55 PM...
MV Water Window ; then press Next. The MV Water Window screen appears. Press the Down Arrow button to select Manual MV Open ; then press Next. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 176 7/16/2012 3:48:56 PM...
Once Run is pressed, stations can be monitored and advanced by turning the dial to the AUTO position and using the Adv button. Press the + and – buttons to increase or decrease Run Time minutes for the current station. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 177 7/16/2012 3:48:56 PM...
Sometimes you may want to turn off the 2-Wire path, such as when Turn off irrigation, master valves or the 2-Wire path. you’re maintaining your system. The ESPLXD-ET controller lets you do Adjust Display Contrast this automatically so you do not need to un-wire the 2-Wire path from the connection lugs.
Page 187
2-Wire Path Off A confirmation screen appears. message will be displayed whenever the controller dial is at the OFF or AUTO dial positions. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 179 7/16/2012 3:48:57 PM...
The All Watering Off screen appears. Press the MV Close button. A confirmation screen appears. To close all master valves, press and hold down the Yes button for four seconds. If you’re not sure, press Back. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 180 7/16/2012 3:48:57 PM...
Connect source power ..............Page 190 Complete controller installation ..........Page 192 Install the Controller This section explains how to mount the ESPLXD-ET controller on a wall Connect ETC Manager cartridge ..........Page 193 (or mounting surface) and connect the wiring. Install local rain gauge (optional) ..........Page 196 NOTE: An optional metal cabinet (LXMM) and pedestal (LXMMPED) are also available for the ESPLXD-ET controller.
Check Box Contents All components below are included with your ESPLXD-ET controller and are required for installation. If anything is missing, please contact your distributor before proceeding. ESPLXD-ET controller. Mounting hardware (5 screws, 5 plastic wall anchors). Controller cabinet keys.
Pull it towards you to open the door, swinging it to the left. To open the controller front panel: grasp the crescent-shaped handle on the right-hand-side of the front panel. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 184 7/16/2012 3:48:59 PM...
NOTE: Removing the antenna knockout with a screwdriver and NOTE: The metal nut should be positioned with the teeth facing hammer is easier if the controller is NOT currently installed. upward, toward the top of the controller case. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 185 7/16/2012 3:48:59 PM...
Use a tapping tool (or nail) and hammer to tap pilot holes through the five mounting hole marks and into the mounting surface. Then remove the template and drill holes in the mounting surface, installing wall anchors if necessary. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 186 7/16/2012 3:49:00 PM...
Install LXD Decoder Module An ESP-LXD-M50 module is required for operation and is included with every ESPLXD-ET controller. The ESP-LXD-M50 module powers and provides an interface from the controller to the two wire path. Carefully fasten the module onto the controller backplane, pressing firmly until it snaps into place.
The controller will manage multiple 2-Wire connections as a single 2-Wire path. The cable must be approved for underground use. Rain Bird recommends use of MAXI Cable, #14 AWG, as your 2-Wire communications cable. WARNING: You must use special precautions when valve wires...
Connecting the 2-Wire Cable Using a thin blade screwdriver, connect the two wire ends to a set of large two-wire path terminals on the ESPLXD-ET decoder NOTE: If installing communications wiring for IQ Software and/ module. When finished, tug gently on the wires to make sure the or ET Manager, do not install the communications cables in the connections are tight.
Connect Ground Wire Remove the screw on the right-hand side and pull the cover off to expose the wiring compartment. The ESPLXD-ET controller is equipped with built-in electrical surge protection. For this system to function, you must properly ground the controller.
Page 199
3 wires Verify that all connections are secure. Then replace the cover of the transformer wiring compartment and secure it with the screw. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 191 7/16/2012 3:49:02 PM...
Complete Controller Installation Programming Under Battery Power The ESPLXD-ET controller front panel can operate under battery WARNING: To prevent electrical shock, make sure all supply power for remote programming. This feature is especially useful if the power is OFF before completing installation. Electrical shock can controller is installed in an area that is not easily accessible.
COMMUNICATION CARTRIDGE BAY LOCAL RAIN GAUGE PORT ET MANAGER RECEIVER/ ANTENNA CABLE PORT ET MANAGER CARTRIDGE ET MANAGER RECEIVER/ ANTENNA CABLE, GROUND WIRE AND OPTIONAL RAIN GAUGE WIRE (NOT SHOWN) ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 193 7/16/2012 3:49:03 PM...
Cartridge. Ensure a secure fit when you here it “click” into place. CAUTION: This connector can only go in one way. Ensure that the ridges on the plug match the slots in the receptacle. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 194 7/16/2012 3:49:03 PM...
Page 203
CAUTION: Ensure that the antenna cable and ground wire do not contact the transformer directly. Heat from the transformer may damage the insulation. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 195 7/16/2012 3:49:04 PM...
Unlatch the ET Manager Cartridge by pressing down on the latch NOTE: If the ribbon cable becomes detached, re-attach with the and pulling forward. RED edge of the ribbon cable toward the LEFT side of the opening. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 196 7/16/2012 3:49:04 PM...
(except when valve-in-head sprinklers WARNING: Use only Rain Bird DB (direct burial) or 3M DBR/DBY are used, which can be directly buried). splice kits for all electrical wiring connections to the 2-Wire path.
Field Decoder Connections Master Valves and MV Decoders Up to five master valves can be connected to the ESPLXD-ET controller Splice one decoder blue wire to the 2-Wire path red wire; then through field decoders attached to the two wire path. Master valves splice the other decoder blue wire to the 2-Wire path black wire.
Follow the field decoder installation process to splice the two blue wires from the flow sensor to the red and black wires in the Splice the blue wires from a Rain Bird LSP-1 to the 2-Wire path in two wire path, completing the splice with approved direct burial the same manner as the installation of a field decoder detailed splice kits.
Decoder Managed Weather Sensors Connect Local Weather Sensors In addition to five flow sensors, ESPLXD-ET can also support three NOTE: Follow the sensor manufacturer’s instructions to correctly decoder-managed weather sensors. Rain Bird SD-210 sensor decoders install and make wire connections to the sensor. Ensure the sensor are used and installed in exactly the same way.
Weather Sensors switch to Active. Once some or all field decoders have been installed and programmed into the ESPLXD-ET controller you can check the electrical portion of the installation even if water is not available to test sprinklers. See Section C, Run a Line Survey for more details.
If the solenoid opens but will not stay open, the holding voltage may be too low. Here, you would change the fifth digit of the code. Use the chart above to select a suitable electrical code for special solenoid (valve) types. ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 203 7/16/2012 3:49:06 PM...
Address in the master valve Address field. The switch code can vary depending on how your system was installed. NOTE: Rain Bird recommends use of a FD-101 for small pump Below, we will cover some of the more common installations.
Use the ET Manager Scheduler software found on the ET Manager Irrigation Amount setting in the ET Manager. Resource CD to determine all settings for your ET Manager Cartridge and ESPLXD-ET Controller. The scheduler software Irrigation Amount requires site information such as: root depth, soil type, and...
PGM A: 0.10” Run Time Minimum Run ET Source Signal Limits Time: 80% Elevation 1000’ Maximum Run Wind Adjust 100% Time: 120% Units English Signal Kc Historical ET (Jan-Dec) 0” ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 208 7/16/2012 3:49:07 PM...
Zone #6 Soil Texture Slope Exposure Root Zone Working Water Storage (RZWWS) Vegetation Crop (Turf) Coefficient (K) Landscape Coefficient (K) Irrigation System Precipitation Rate (PR) Estimated Application Efficiency Gross Area ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 210 7/16/2012 3:49:09 PM...
Page 219
000, I: 000, J: Rainfall Source Irrigation Amount for each Program Run Time for each Station Cycle+Soak Time for each Station Day Cycle for each Program Start Time for each Program ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 211 7/16/2012 3:49:09 PM...
Rain Bird Specifications Hotline (800) 458-3005 (U.S. and Canada only) Rain Bird Corporation 6991 East Southpoint Road, Tucson, AZ 85756 Phone: (520) 741-6100 Fax: (520) 741-6522 Visit us at www.rainbird.com ESPLXD-ET Controller ESPLXD-ET user-manual (670504-01) artwork_120716.indb 212 7/16/2012 3:49:09 PM...
Page 221
ESPLXD-ET Model Numbers: I the undersigned, hereby declare that the equipment specified above conforms to the above Directive(s) and Standard(s). Tucson, AZ USA Place: Signature: Ryan L. Walker Full Name: Director Position: ESPLXD-ET user-manual (670504-01) artwork_120716.indb 3 7/16/2012 3:49:09 PM...
Page 224
However, there is no guarantee that interference will not Changes or modifications not expressly approved by Rain Bird Sales, Inc., could void occur in a particular installation.