Rs232C Settings - Sanyo CE42LM4WPR-E Service Manual

Hide thumbs Also See for CE42LM4WPR-E:
Table of Contents

Advertisement

RS232C SETTINGS

The TV control commands are used to control a TV through RS232C from a computer.
Serial Interface Specification
Transfer Specification
1. Transmission Speed : initial setting value is 19200
2. Transmission speed can be changed by hotel mode
ITEM
Synchronous system
Transmission Speed
Data Length
Parity
Stop Bit
Flow Control
Connection
The designated RS232C serial cable that is provided with the LCD monitor must be used for a connection between a computer and a LCD monitor
1
CD
2
RXD
3
TXD
4
DTR
SG
5
6
DSR
7
RTS
8
CTS
9
RING
(D-Sub 9 Pin)
The TV command is defined by one command / one line that starts with "C" and ends with carriage return (0x0D)
There are two types of commands:
1. Functional Execution Commands e.g. Co5[CR] (see table on following page)
2. Status Read Commands e.g. "CR0 [CR] (see table on following page)
Setting the monitor address in RS232 mode
To access hotel mode press the green button on the remote control and hold for 5 seconds. The following screen will appear
Hotel
Hotel mode
On program
Preset
Address
Baud Rate
: Select
Each monitor can have a specific address e.g. 007 which helps command that monitor individually and will not affect other monitors connected to
a controlling pc.
Address format command
The adressing format command is used for operating multiple monitor sets from a single pc via the RS232 command line. If you set your monitor
address to '000' it will never respond to any addressing command from the pc. If the address from the pc is 'FFF', all monitor sets will execute the
command.
The address format command is defined by one command, one line which starts with 'A' and ends with carriage return (0x0D). An address is
added at the top of a control command.
Example:
Functional execution command: "A001C05" [CR] means the address is 001 and the control command is C05
Status read command: "A001CR0" [CR] means the address is 001 and the command is CR0
The monitor can set its own address in the hotel option (see above). The address range is 000 - 999, the default address will be 000.
The baud rate indicates the unit transfer speed of data from the pc the the monitor sets.
N4JK
SPECIFICATION
Asynchronous
9600 / 19200
8 bit
None
1
None
1
N.C.
2
RXD
3
TXD
4
N.C
5
SG
6
N.C
7
RTS
8
CTS
9
N.C.
(D-Sub 9 Pin)
ON / OFF
OFF/ 1~99
/ AV1-AV3 /RGB/ HDMI/ PC
ON / OFF
007
19200
: Adjust
: Exit
MENU
-16-

Advertisement

Table of Contents
loading

Table of Contents