First Firing; Odor During Operation; Flame Adjustment; Flame Characteristics - Vermont Castings RFSUV34 Homeowner's Installation And Operating Instructions Manual

Unvented freestanding fireplace
Table of Contents

Advertisement

RFSUV34 Vent-Free Heater
Replacement lava rock must be pur-
chased through our dealers.
Application of excess loose material
may adversely affect performance of the
heater.
WARNING: All previously applied loose
material must be removed prior to reap-
plication.

First Firing

Upon completing your gas line connection, a small amount
of air will be in the lines. When first lighting unit with pilot
light, it will take a few minutes to purge this air. Once the
purging is complete, the pilot and burner will light and op-
erate as indicated in the instruction manual. Subsequent
lightings of the heater will not require such purging.

Odor During Operation

Neither natural gas nor propane gas give off an odor
when burned. The nature of a vent free combustion
system, however, is such that odors may occasionally
be produced during heater operation when impurities
exist in the immediate area. Cleaning solutions, paint,
solvents, cigarette smoke, candles, adhesives, new car-
pet or textiles, etc., all can create fumes. These fumes
may mix with combustion air and can create odor. Such
odors will disappear over time, however, the condition
can be alleviated by opening a window or otherwise
providing additional ventilation to the area.

Flame Adjustment

For units equipped with Hi/Lo valves, flame adjustment
is accomplished by rotating the Hi/Lo adjustment knob
located near the center of the gas control. (Fig. 10)
Turn
counterclockwise
to decrease
flame height
Fig. 10 Flame adjustment on gas valve (standing pilot only).
8
HV102
Honeywell hi/lo knob
4/5/99 djt
Fig. 9 Correct burner lava rock placement.
Turn clockwise
to increase
flame height
Lava Rock Area

Flame Characteristics

It is important to periodically perform a visual check of
the pilot and the burner flames. Compare them to the
�����
illustrations below. (Figs. 11 & 12)
������� ���� ���� ���������
����
Fig.11 Correct pilot flame appearance.
FP449a
Sit pilot no thermo generator
12/02
Fig. 12 Approximate flame height.
�����
������� ��� �����
LG437
FP449a
LG438
10001769

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents