Pioneer YN018GMFI16M2D Service Manual page 54

Hide thumbs Also See for YN018GMFI16M2D:
Table of Contents

Advertisement

Appendix 5:
Spec.
Model
Compressor
Outdoor fan motor
Model
Indoor fan motor
Model
Indoor fan motor
Model
Indoor fan motor
Model
Indoor fan motor
Model
Indoor fan motor
1.
Compressor checking
Measure the resistance value of each winding by using the tester.
Position
Blue - Red
1x2
DA130S1C-20FZ
YDK70-6FB
9k Wall
RPG20B
9k Wall
RPG20B
/
/
/
/
/
/
DA130S1C-20FZ
0.95Ω(20 ℃ )
Outdoor unit
1x3
DA150S1C-20FZ
YDK70-6FB
Indoor unit
12k Wall
RPG20B
12k Wall
RPG20B
12k A5
YSK27-4G
12k Cassette
YDK45-6B
12k Ceiling&Floor
YSK25-6L
Resistance Value
DA150S1C-20FZ
0.95Ω(20 ℃ )
1x4
TNB306FPGMC-L
YDK180-8GB
18k Wall
RPG28H
18k Wall
RPG28H
18k A5
YSK68-4B
18k Cassette
YDK45-6B
18k Ceiling&Floor
YSK25-6L
TNB306FPGMC-L
0.53Ω(20 ℃ )