24
C indoor unit room temp.(T
25
D indoor unit room temp.(T
26
E indoor unit room temp.(T
27
A indoor unit evaporator outlet temp.(T
28
B indoor unit evaporator outlet temp.(T
29
C indoor unit evaporator outlet temp.(T
30
D indoor unit evaporator outlet temp.(T
31
E indoor unit evaporator outlet temp.(T
32
Condenser pipe temp.(T3)
33
Outdoor ambient temp.(T4)
34
Compressor discharge temp.(Tp)
35
AD value of current
36
AD value of voltage
37
EXV open angle for A indoor unit
38
EXV open angle for B indoor unit
39
EXV open angle for C indoor unit
40
EXV open angle for D indoor unit
41
EXV open angle for E indoor unit
42
Frequency limit symbol
43
Average value of T2
44
Outdoor unit fan motor state
45
The last error or protection code
C)
1
D)
1
E)
1
A)
2B
B)
2B
C)
If the temp. is lower than -9 degree, the digital display tube will
2B
show "-9".If the temp. is higher than 70 degree, the digital display
D)
2B
tube will show "70". If the indoor unit is not connected, the digital
E)
display tube will show: "――"
2B
The display value is between 30~120 degree. If the temp. is lower
than 30 degree, the digital display tube will show "30".If the temp.
is higher than 99 degree, the digital display tube will show single
digit and tens digit. For example, the digital display tube show
"0.5",it means the compressor discharge temp. is 105 degree.)
The display value is hex number.
Actual data/4.
If the value is higher than 99, the digital display tube will show
single digit and tens digit.
For example ,the digital display tube show "2.0",it means the EXV
open angle is 120×4=480p.)
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
(Sum T2 value of all indoor units)/(indoor units number)
Off:0, High speed:1, Med speed:2, Low speed:3
00 means no malfunction
0
0
Frequency limit caused by T4.
Frequency limit caused by T2.
Frequency limit caused by T3.
Frequency limit caused by Tp.
Frequency limit caused by current
Frequency limit caused by voltage
The display
value is hex
number. For
example, the
digital display
tube show
2A,then Bit5=1,
Bit3=1, Bit1=1.
It means
frequency limit
caused by
T4,T3 and
current.