6. Setting items (* Item names and selective items are expressed in English.)
1) Power ON fixed [POWER ON FIXED]
Option
"VARIABLE","FIXED_ALL", "FIXED_BODYKEY" or "RCRESPOND" (loop enabled)
Default
"VARIABLE"
Function
Key disabled when set
other than default
If the power button is pressed in the ordinary mode in setting to "FIXED_ALL", the caution is displayed for 5 seconds.
When power button on the main unit is pressed
No Power off by power button.
* The OSD display is an example.
If another ODS is previously displayed, the status is reset (MENU or similar).
2) Instantaneous current shutdown setting in turning off the power [SHUT DOWN MODE]
Option
"NORMAL" or "QUICK"
Default
NORMAL
Function
This function decides whether scanning digital tuner is enabled or disabled when the power is standby.
NORMAL
QUICK
Remarks
In selecting "QUICK", the function does not work for the following items
(selection impossible.)
ON TIMER, QUICK START, DIGITAL FIXED, etc.
3) Volume maximum level [MAXIMUM VOLUME]
Option
0~60(loopdisabled)
Default
60
Function
The volume cannot be increased more than the adjusted value (the main unit's speaker only).
Remarks
In setting to 59 or less, only the figure is displayed in the normal mode; the volume bar is not displayed.
The volume of the headphones or monitor output is limited.
The setting is impossible when VOLUME FIXED is set other than VARIABLE.
VARIABLE
: "POWER/RECEPTION" key on TV unit or remote control is enabled
FIXED_ALL
: "POWER/RECEPTION" key on TV unit or remote control is disabled.
FIXED_BODYKEY
: only the "MAIN POWER" key on TV unit is disabled
(the remote control is enabled).
RC RESPOND
: the main unit's POWER switch toggles between ON and Standby
(the same operation by the remote control).
OFF TIMER (SLEEP)
In selecting to "FIXED_ALL", function related standby factors (see below) doesn't work. and not selecting
OFF TIMER (Sleep)
No operation OFF
No signal OFF (including the power management)
: Scanning digital tuner is enabled when the power is standby.
: Scanning digital tuner is disable
It is possible to put into the standby state instantaneously due to power off input, when the power is standby.
Immediately, state is a complete standby.
When power buttonon R/C is pressed
No Power off by remote control.
5 – 9