Century FW2600 Installation And Operation Manual page 28

Hide thumbs Also See for FW2600:
Table of Contents

Advertisement

Century FW2600 Installation and Operation Manual
CLEARANCES
(SINGLE WALL PIPE)
CANADA
A
19" (483 mm)
B
21" (533 mm)
C
16" (406 mm)
D
23½ (597 mm)
E
29¼ (743 mm)
F
25¼ (641 mm)
K
48" (1219 mm)
L
72" (183 cm)
Note: Clearances for single wall are also valid for an alcove installation.
Clearances for mobile homes
A
B
C
D
E
F
K
L
28
USA
19" (483 mm)
21" (533 mm)
16" (406 mm)
23½ (597 mm)
29¼ (743 mm)
25¼ (641 mm)
48" (1219 mm)
72" (183 cm)
MOBILE HOME CLEARANCES (DOUBLE WALL
CANADA
10" (254 mm)
21" (533 mm)
12" (305 mm)
14½ (368 mm)
29¼ (743 mm)
21¼ (540 mm)
48" (1219 mm)
84" (213 cm)
CLEARANCES
(DOUBLE WALL PIPE)
CANADA
A
7" (178 mm)
B
21" (533 mm)
C
12" (305 mm)
D
11½ (292 mm)
E
29¼ (743 mm)
F
21¼ (540 mm)
K
48" (1219 mm)
L
72" (183 cm)
PIPE)
USA
10" (254 mm)
21" (533 mm)
12" (305 mm)
14½ (368 mm)
29¼ (743 mm)
21¼ (540 mm)
48" (1219 mm)
84" (213 cm)
USA
7" (178 mm)
21" (533 mm)
12" (305 mm)
11½ (292 mm)
29¼ (743 mm)
21¼ (540 mm)
48" (1219 mm)
72" (183 cm)

Advertisement