Memrecam GX-5 User Manual page 172

High speed digital camera system
Table of Contents

Advertisement

8.1.4 GX-HUB (G-resistant model)
1) Number of GX camera connections
2) Power input
3) Power switch
4) Exterior dimensions
5) Weight
6) Operating temperature and humidity -10~+40℃, 20~80%RH, (no condensation)
7) Storage temperature and humidity
8) Vibration
9) Shock
10)Front port
・Individual input (BNC Connector x 3) IRIG IN, TRIG IN, EST IN
・GXSYS(LEMO Connector : EGG.2B.318) :GX-HUB, or branch input/output using J3 cable
Gbit Ethernet, EPO(4 port OR output), IRIG IN, TRIG IN, EST IN,POWER CONT
・FXSYS (MIL Connector ACT90MC35SA):connect with fx series M-HUB corresponds to fx
series camera
・Priority order is FXSYS > GXSYS > individual input
11)Back port
12)LED display
8.1.5 Booster Box (G-resistant model)
1)
Operating temperature and humidity 0~40℃, 30~80%RH (no condensation)
2)
Storage temperature and humidity
3)
Vibration
4)
Shock
5)
Cables
6)
Exterior dimensions of cable
(00200)
4
DC20 ~ 32V, power consumption : maximum 12 W,
AC adapter included
Yes、GX-HUB and camera link function ON/OFF
Approximately W280 x H75 x D230 mm (Without connector
etc)
Approximately 4.1 kg (Include mounting plate)
-20~+60℃, 20~80%RH, (no condensation)
MIL-STD-810C METHOD 514.2 CATEGORY b2 standard
(RANDOM VIBRATION ENVELOPE) FIGURE514.2-2A
half-sine, 11msec, 100G
GXSYS(LEMO Connector FWG.2B.318) 4 ports
GX series camera J3 Connector or GX-HUB GXSYS and J3
remote cable connection
IRIG, TRIG, EST, LINK(Gbit Ethernet), POWER
-10~60℃, 20~80%RH (no condensation)
MIL-STD-810C METHOD 514.2 CATEGORY b2 Standard
(RANDOM VIBRATION ENVELOPE) FIGURE514.2-2A
half-sine, 11msec, 150G (However, it is 100G only by one axis.)
Pig tail structure:Length Approximately 5m
Approximately 12.9mm
8-3