5.2.5.
Fax Service Mode 4 (Modem Test)
5.2.5.1.
Binary Signal
This Service Mode is used to check the binary signal output. Signals can be output to the line using the
following procedure.
Press the "V", "/\" arrow keys to select the "4: MODEM Test" on the display.
↓
Press the "SET" key to select the "1: Signal Test".
↓
Press the "SET" key.
↓
Press the desired number.
↓
Press the "SET" key.
↓
Press the "STOP" key twice to exit the service mode.
Ver. 1.0
Binary Signal Table
Number
Signals
1
V21 300bps
2
V27ter 2400bps
3
V27ter 4800bps
4
V29 7200bps
5
V29 9600bps
6
V17 TC7200bps
7
V17 TC9600bps
8
V17 12000bps
9
V17 14400bps
290
DP-8020E/8020P/8016P
SEP 2006