Troubleshooting; No Led Indication; Red Led Flashes Rapidly - RCA BR250 Instruction Manual

Vhf two-way radio uhf two-way radio
Table of Contents

Advertisement

14

Troubleshooting:

When troubleshooting, always observe the
color of the LED:

No LED Indication

1. Make sure that the power cord is plugged
into an appropriate AC outlet.
Red LED flashes rapidly (0.2s on/0.2s off)
Remove the battery from the charger, and:
1. Make sure that you are using an original
RCA Communications Systems battery.
Remove power from the battery charger.
Clean the charger and the battery's
charging contacts using a clean, dry cloth.
2. Make sure the battery temperature isn't
above 113°F. (45°C)
3. Power up the charger and place the
battery back into the charging cup. If the
LED indicator continues to flash red, most
likely, the battery can no longer be charged
and must be replaced. To determine if the
BR250
Professional Two-Way Radio Instruction Manual
TM
Copyright © 2015 RCA Communications Systems
battery
requires replacement, place the
battery pack into another charger that
you know is working properly. If the LED
continually flashes red, battery replacement
is necessary.
Notes:
• When the battery charger detects the
proper battery conditions, rapid charging
begins automatically (steady red LED).
• If the battery temperature is above 113°F
(45°C), the charger will report the fault by
flashing the red LED rapidly (0.2s on/0.2s
off), and will not charge until the battery
temperature is below 113°F (45°C) with
the red LED changing to solid illumination.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents