HARBOR POINT WALL SPLIT DUCTLESS SYSTEMS
 
Determine the best location for mounting
the indoor unit, it must be located a mini-
mum of 4 ft (6 ft or more recommended)
from the floor and no less than 6" from
the ceiling.
Pay attention to the air circulation in the
room, 9,000 & 12,000 Btu units throw air
15ft, 18,000 & 24,000 Btu units throw air
25ft, ensure no obstacles to airflow exist.
Locate the indoor and outdoor units as close
together as possible, maximum line set run
and lift MUST NOT BE EXCEEDED. Deter-
mine how the interconnect piping, wiring
and condensate hose are to be run.
Unit
HF-25/HF-35
HF-25/HF-35
HF-51/HF-70
HF-51/HF-70
HFR-25/HFR-35
HFR-25/HFR-35
HFR-51/HFR-70
HFR-51/HFR-70
Ensure that all panels can be removed for
service as required.
Certification:
All Harbor Point Systems are certified by
UL under UL Standard 1995. Per-
formance is varified by CSA under ARI
210/240 test standard.
PRE INSTALLATION
Max
Max Line
Vertical
Set Run
Lift
50 Feet
50 Feet
17 Feet
17 Feet
50 Feet
50 Feet
17 Feet
17 Feet
50 Feet
50 Feet
17 Feet
17 Feet
50 Feet
50 Feet
17 Feet
17 Feet
CONTROLS AND COMPONENTS
Units are supplied with a wireless remote
control, which communicates with the unit
microprocessor control. The return air
temperature sensor mounted in the in-
door unit provides input to the control for
system operation.
Several modes of operation are available
to the end user depending on the type of
comfort required. All unit operating func-
tions are controlled via the remote con-
trol. Refer to "System Operation" section
of this manual.
OPTIONAL CONTROLS AND
COMPONENTS
Low Ambient Control:
Please consult the factory for availability of
approved method of low ambient cooling
operation.
Condensate Pump:
It is recommended to use the supplied
condensate drain hose in a gravity fed
method whenever possible. If this can
not be done then a field installed pump
that is external to the evaporator would
be required.