Download Print this page

Intended Use Of The Heat Pump; Intended Purpose; Operating Principle; Basic Device - Dimplex SIH 90TU Operating Instructions Manual

Brine-to-water
Hide thumbs Also See for SIH 90TU:

Advertisement

Available languages

Available languages

2
Intended use of the heat
pump

2.1 Intended purpose

The brine-to-water heat pump is to be used exclusively for the
heating of heating water. It can be used in new or existing heat-
ing systems. A mixture of water and frost protection (brine) is
used as a heat transfer medium in the heat source system. Bore-
hole heat exchangers, ground heat collectors or similar systems
can be used as the heat source system.

2.2 Operating principle

The heat generated by the sun, wind and rain is stored in the
ground. This heat stored in the ground is collected at a low tem-
perature by the brine circulating in the ground heat collector, the
borehole heat exchanger or a similar system. A circulating pump
then conveys the "heated" brine to the evaporator of the heat
pump. There the heat is given off to the refrigerant in the refriger-
ation circuit. This cools the brine so that it can once again absorb
thermal energy in the brine circuit.
The refrigerant is drawn in by the electrically driven compressor,
compressed and "pumped" to a higher temperature level. The
electrical power needed to run the compressor is not lost in this
process. Most of it is absorbed by the refrigerant.
The refrigerant subsequently passes through the liquifier where it
transfers its thermal energy to the heating water. Depending on
the set operating point (thermostat setting), the heating water
can thus be heated up to a max. of 70 °C.
www.dimplex.de
3

Basic device

The device consists of a heat pump for indoor installation wired
ready for use with metal casing, switch box and integrated heat
pump manager. The refrigeration circuit contains the Kyoto pro-
tocol-approved fluorinated refrigerant R134A with a GWP value
of 1300. It is CFC-free, does not deplete ozone and is non-flam-
mable.
All components required for the operation of the heat pump are
located in the switch box. An outside temperature sensor includ-
ing fixing accessories and a dirt trap are supplied with the heat
pump. The supply for the load current and the control voltage
must be installed by the customer.
The brine pump is activated via the switch box. It must be
equipped with a motor protection device, if required.
The customer must provide both the heat source system and the
brine circuit manifold.
1)
Switch box
2)
Evaporator
3)
Liquefier
4)
Compressor
5)
Filter dryer
6)
Economiser
452234.66.54 · FD 9401
SIH 90TU
EN3

Advertisement

loading