8-2. Primary Judgement of Trouble Sources

8-2-1. Role of Indoor Unit Controller
The indoor unit controller receives the operation com-
mands from the remote control and assumes the fol-
lowing functions.
Measurement of the draft air temperature of the
indoor heat exchanger by using the temperature
sensor (T
)
A
Louver motor control
Control of the indoor fan motor operation
Control of the LED display
Control of the outdoor unit compressor and the
outdoor fan motor.
Block display
OPERATION display flashing (1 Hz)
OPERATION display flashing (5 Hz)
OPERATION display flashing (5 Hz)
OPERATION display flashing (5 Hz)
OPERATION display flashing (5 Hz)
OPERATION and TIMER display flashing
(5 Hz)
OPERATION, TIMER and FAN ONLY display
flashing (5 Hz)
OPERATION, TIMER and FAN ONLY display
flashing (5 Hz)
(1) Judgement from defective operation or abnormal operation
System
No reaction on remote control
operation
The outdoor fan does not
rotate
Table 8-2
Check
code
Power failure (When power is on)
Temperature sensor (T
Heat exchanger sensor (T
Indoor fan lock, abnormality of indoor fan,
IC03, D15 short/break
Indoor PC board failure
• Thermal fuse is blown
(Indoor fan motor is overheat)
• Gas shortage, other refrigerant cycle
trouble
• Heat exchanger sensor open/short/break
• Overload relay trouble
Compressor trouble
Table 8-3
Check
Turn off the power
Remote control is not
once, turn it on again
possible.
and try to operate the
Remote control is
remote control again.
possible.
The compressor operates.
The compressor does not operate.
– 15 –
8-2-2. Display of Abnormalities and Judgement
of the Abnormal Spots
The indoor unit of this machine observes the opera-
tion condition of the air conditioner and displays the
contents of the self-diagnosis as block displays on
the display panel of the indoor unit.
Self-diagnosis
) short/break
A
) short/break
C
The indoor part (including the
remote control) is defective.
O.K.
The outdoor part is defective
(outdoor fan motor)
The inside part is defective.
Check
code
Primary judgement