6. To remove high voltage capacitor.
(1) Remove a screw which secure the grounding ring terminal
of the H.V.diode and the capacitor holder.
(2) Remove the H.V. diode from the capacitor holder.
(3) Reverse the above steps for reassembly.
High voltage circuit wirng
7. To remove magnetron.
(1) Remove a screw which secure the magnetron.
(2) Remove the magnetron.
(3) Reverse the above steps for reassembly.
CAUTION
Never install the magnetron without the metallic gasket plate which is packed with each magnetron to prevent micro-
wave leakage. Whenever repair work is carried out on magnetron, check the microwave leakage. It shall not exceed
2
4mW/cm
for a fully assembled oven with door normally closed.