7.11 Motorized drip tray

Loosen the screws as indicated.
Pull the motorized tray towards you.

Disassembling the motorized tank stepper motor

Loosen the two screws to release
the electric motor with worm gear
TALEA Section 07
REV00 - August 06
Ideas with Passion
To reach the capacitive sensors, loosen
the two screws to remove the safety
guard under the drip tray.
Remove electrical connections (G) as indi-
cated.
To withdraw the stop (A) use pliers to grip the tabs
securing the lifting system to the base and pull out-
wards. Withdraw the electric motor with worm gear
from above.