PROBLEM
POSSIBLE CAUSE
a. Wine tube restricted
b. Bottle near empty and there is too
Wine spurting or
spitting
c. Nitrogen pressure too high
d. Wine solenoid valve is dirty
a. Solenoid valve seat leak
Wine dripping
b. Spout leak at solenoid valve fitting
a. Wine tube leak
Spout drop
b. Empty bottles
a. Debris in spout
Wine divided
a. Argon/Nitrogen pressure is too
Too many bubbles
a. Bottle is not tightened
Gas escaping
b. Gas tube broken
1 7 6 2 1 S o u t h S u s a n a R o a d , R a n c h o D o m i n g u e z , C a l i f o r n i a 9 0 2 2 1
TROUBLESHOOTING
much nitrogen in the bottle
high
i n f o @ v i n o t e m p . c o m
RESPONSE
a. Check for restrictions
b. Change out the bottles
c. Reduce nitrogen pressure to 3 psig
d. Clean solenoid valves
a. Check for debris if dripping is constant
b. Push to tighten spout if there is intermittent
dripping
a. Check the wine tube
b. Change out the bottles
a. Clean out debris
a. Reduce gas pressure to 3 psig
a. Check the plug/fixer
b. Check the gas tubes