Page 7
Press and hold the wine dispensing button to empyt the remaining gas in the cartridge Unplug the unit Rotate the cover upwards to access the gas cartridge Pull the cartridge and turn it counter clockwise to loose Place a new cartridge and align it to the neck thread of regulator rotatge it clockkwise only turn to position properly then turn clockwise all the way to tighten...
Page 10
Complaint Possible Causes Response a Argon Nitrogen empty a Check for cylinder pressue b Bottle not tightened b Check for bottle fixer and if gas escaping c Defective bottle plug c Check for bottle plug and if gas escaping d Gas tubing blockage d Check for gas tubes e Defective gas solenoid valve e Remove bottle press button to check if gas escaping...
Page 11
Complaint Response Possible Causes a Wine tube restricted a Check any restrictions b Bottle near empty and too much nitrogen b Change a new bottle in the bottle c Nitrogen ptessure too high c Reduce the pressure to 3 psig d Wine solenoid valve dirty d Clean solenoid valves a Solenoid valve seat leak...