Notes for repairing chair or replacing parts:
①Make sure the power is OFF before tearing down the wires, moving terminals or replacing
parts.
②Semiconductors (such as IC and others) are very easy to be damaged by static, so when you
touch the PCB, please make sure your body is grounding (by wearing a girding static ring), or
your hands are touching with earthing grip (household electrical appliances putting to earth, such
as fridges, washers and so on) to release all static of the body.
1. No function when starting.
Is the LCD
illuminating?
Y
Are the terminals of Up
and
Down
Stroke
Subassembly connected
securely?
Y
The switches of Up and Down
Stroke Subassembly fail or not?
N
Is kneading on without pressing any
key when starting?
N
Width Inspection
Board fails or not?
V. Troubleshooting flow chart
N
Connect
N
securely.
Y
Replace
Y
Replace Width
Inspection Board.
N
Is the fuse melted?
N
Is the power cord
open-circuit?
N
The EMC Board
fails or not?
N
Replace main PCB.
8
Y
Replace fuse.
Y
Replace power
cord.
Y
Replace it.