Installation
Instructions
[_] REMOVE EXHAUST
ADAPTOR
If exhausting/venting
using the 31/W' x 10" rectangular
duct--optional
for JV247, JV248, JV338, JV347, JV348,
JV367 and AV447 models only:
Remove the exhaust adaptor from the inside of the hood.
Set it aside along with its mounting screws.
_-] REMOVE WIRING COVER
Remove the wiring cover from inside the hood.
Set the cover and its mounting screws aside.
Wiring
cover
[] REMOVE FILTER
Remove the shipping tape holding the metal grease
filter in place. Pull down on the center of the front edge
of the filter. The filter will then slip out of the retaining
tabs on the back.
Metal grease filter
[] REVERSE THE BAFFLE FOR DUCTED
INSTALLATIONS
ONLY
(JV247,
JV248,
JV347, JV348,
JV367 and AV447
models)
If the hood is to be recirculated, skip to the next step.
Removethe baffle from the top of the hood. Reinstall
the baffle so the short side marked "VENTED" is visible.
The long side of the baffle should be inside the hood.
"VENTED" i svisible
[_] REMOVE WIRING KNOCKOUT
Remove either the top or the back wiring knockout as
needed and install an approved strain relief clamp.
Top
Back
knockout
knockout
Strain relief X
Strainrelief
clamp
clamp
[_ REMOVE DUCT KNOCKOUT
If recirculating, non-vented ductless (JN327 and RN328,
and optional for JV247, JV248, JV347, JV348, JV367 and
AV447 models only), skip to Step 11 D and proceed.
Using a flat-blade screwdriver, remove the appropriate
duct knockout from the top or back of the hood.
3¼" x 10" Rectongu!ar
vertical discharge.
Remove top rectangular
duct knockout only.
7" Round vertical discharge.
Remove circular duct
knockout only.
10
3k'J' x 10"Rectangular horizontal
discharge. Remove rear
rectangular duct knockout only.