Installation
Instructions
INSTALLATION--ELECTRICAL
CONNECTIONS
D
When making the wire connections,
use the
entire length of conduit provided. The conduit
must not be shortened.
With the cooktop
in place, open the front of
the cabinet door.
Insert the wires from the conduit through
the
openinq of the junction box.
Ground
Red __
Black
Strain
Relief Clamp
[]
Connect the red and black leads from the
cooktop conduit to the corresponding
leads
in the junction
box.
Ground
wire
location
_
Red
Black
r_
Once the connections
are made, secure wires
together
using wire nuts.
Red
Strain
Relief Clamp
Ground
/
_
Black
GROUNDING INSTRUCTIONS:
The bare ground wire in the conduit
is connected
to the cooktop
frame.
Effective
January
1, 1996,
the National
Electrical
Code will not permit
grounding
through
neutral.
If used in new
construction
after January 1, 1996 or in a mobile
home, recreational
vehicle or if local codes do
not permit
grounding
through
the neutral
white
lead, attach
the appliance
grounding
lead (green
or copper) to the residence
grounding
conductor
(green or bare copper)
in accordance
with local
codes. When connecting
to a 3 conductor
branch
circuit,
if local codes permit,
connect
the bare
ground
connector
lead of the cooktop
to the
branch
circuit
neutral
(gray or white in color).
IMPORTANT:
If the cooktop
is being
installed
into
a blind
counter
(one with
no
cabinet
opening
below),
wire connections
must
be made
before
putting
the cooktop
into the
cutout
opening.