A grounded 3 prong electrical outlet should be located within
a specified number of inches from the right-hand side
cabinets or end panel. See the chart following the graphic for
the number of inches required for your model. For more
information, see "Electrical Requirements."
The water shutoff should be located in the base cabinet on
either side of the refrigerator or some other easily accessible
area. If the water shutoff valve is not in the cabinets, the
plumbing for the water line can come through the floor or the
back wall. See "Water Supply Requirements"
for more
information.
0
it
JJ
JJ
ii 80"-g0" ii
i i(203-229 cm)ii
II
831/2" (212.1 cm) min.
843/4" (215 cm) max.
to bottom of solid soffit
A
Width
(see chart following)
/
ii
Dimension
77"
(196 cm)
r
t
I
(15.2 c
24"
(60.96 cm) rain.
Width A
Width A for
Dimension
B
(as shown
Overlay Models
(as shown
Model
above)
(as shown above)
above)
36
351/2"to 353/4 ''
353/4'' to 36"
4" (10.2 cm)
(90.2 cm to
(90.8 cm to
90.8 cm)
91.4 cm)
42
411/2"to 413/4"
413/4" to 42"
10" (25.4 cm)
(105.4 cm to
(106 cm to
106 cm)
106.7 cm)
48
471/2 '' to 473/4 ''
473/4'' to 48"
16" (40.6 cm)
(120.7 cm to
(121.3 cm to
121.3 cm)
121.9 cm)
NOTE: Flooring under refrigerator must be at same level as the
room. Face of cabinetry must be plumb.
£:i',1 @ CI:
/_,,@ ;]!
Electrical
Shock Hazard
Plug into a grounded
3 prong outlet.
Do not remove ground
prong.
Do not use an adapter.
Do not use an extension
cord.
Failure to follow these instructions can result in death,
fire, or electrical
shock.
Before you move your refrigerator into its final location, it is
important to make sure you have the proper electrical
connection.
Recommended
Grounding
Method
A 115 volt, 60 Hz., AC only, 15- or 20-amp fused, grounded
electrical supply is required. It is recommended
that a separate
circuit serving only your refrigerator be provided. Use an outlet
that cannot be turned off by a switch. Do not use an
extension cord.
IMPORTANT:
If this product is connected to a GFCI (Ground
Fault Circuit Interrupter) protected outlet, nuisance tripping of the
power supply may occur, resulting in loss of cooling. Food quality
and flavor may be affected. If nuisance tripping has occurred,
and if the condition of the food appears poor, dispose of it.
NOTE: Before performing any type of installation, cleaning, or
removing a light bulb, remove the top grille and turn the master
power switch to OFF or disconnect
power at the circuit breaker
box.
When you are finished, turn ON the master power switch or
reconnect power at the circuit breaker box. Then reset the control
to the desired setting.

Advertisement