Download Print this page

Crosley CRG3480GWWC Instructions

Advertisement

Quick Links

INSTALLATION AND SERVICE MUST BE PERFORMED BY
A QUALIFIED INSTALLER.
IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
This conversion
kit must be installed by a qualified service technician
in accordance with the
manufacturer's instructions and all applicable codes and requirements of the authority having jurisdiction.
Failure
to follow instructions may result in fire, explosion or production of carbon monoxide causing property damage,
personal injury or loss of life. The qualified service agency is responsible for the proper installation of this kit. The
installation is not proper and complete until the operation of the converted appliance is checked as specified in
the manufacturer's
instructions supplied with this kit.
Before proceeding with the conversion,
shut off the gas supply before disconnecting
electrical
power to the range. Be sure both power supplies are off before installing the conversion kit. Failure to do so could
cause serious bodily injury.
Determine the combination of top burners that are featured
on your range. Identify the parts you need from this kit to com-
plete the L.P. conversion. When burners are converted from Natural to L.P. the BTU ratings are as follows:
5,000 BTU* Natural Gas to 4,500 BTU* L.P. Gas
9,500 BTU* Natural Gas to 8,000 BTU* L.P Gas
12,000 BTU* Natural Gas to 10,000 BTU* L.P. Gas
Quantity
Part Number
Part Description
316037527
L.P. Conversion Kit Label
316417504
1
1
1
1
1
1
1
1
1
1
1
1
1
1
4
1
1
1
1
1
1
1
1
1
14,000 BTU* Natural Gas to 11,000 BTU* L.P. Gas
16,000 BTU* Natural Gas to 14,000 BTU* L.P. Gas
Notes
English & French
Instructions for converting range to L.P. Gas
English, French & Spanish
316005215
316005216
316005217
316005218
316005219
316005220
316005221
316005222
316241200
316237910
316237904
316237905
316237906
316237907
316005223
316005224
316005225
316005226
316005227
316005228
316005229
316005230
Rating Plate - English
Rating Plate - English
Rating Plate - English
Rating Plate - English
Rating Plate - French
Rating Plate - French
Rating Plate - French
Rating Plate - French
L.P. Conversion Label
Orifice - 14,000 BTU*
Orifice - 11,000 BTU*
Orifice - 10,000 BTU*
Orifice - 8,000 BTU*
Orifice - 4,500 BTU*
Rating Plate - English
Rating Plate - French
Rating Plate - English
Rating Plate - French
Rating Plate - English
Rating Plate - French
Rating Plate - English
Rating Plate - French
4- 8k
3+1
2+1+1
1+1+1+1
4- 8k
3+1
2+1+1
1+1+1+1
English, French & Spanish
Black
Red
Green
No Color
Blue
1-11k, 2-8k, 1-4.5k
1-11k, 2-8k, 1-4.5k
1-11k + 3-8k
1-11k + 3-8k
1-14k, 1-10-k, 1-8k, 1-4.5k
1-14k, 1-10-k, 1-8k, 1-4.5k
1-14k, 1-10-k, 1-8k, 1-4.5k
1-14k, 1-10-k, 1-8k, 1-4.5k
*Note: For o oeration at elevations above 2000 ft., appliance rating shall be reduced at the rate of 4 percent for each 1000 ft. above
sea level.
IMPORTANT:
After replacing
the natural gas to LP orifices,
be sure to keep the original
factory
installed
natural
gas orifices
for future
range conversion
back to natural gas. The factory
orifices
are marked with 101 for 5,000 BTU;
Tools Required
for L.P. Conversion:
3/8", 1/2" and 5/8" Open
End Wrench
1/8" Wide
Flat Blade
Screwdriver
_
& 7mm Nutdriver
pin 316417504
(0407)
1
Frangais-
Pages 6-10
Espa5ol - Paginas 11-15

Advertisement

loading

This manual is also suitable for:

Crg3480gwbcCrg3160gbbbCrg3490gbbaCrg3490gwwaCrg3140gwbbCrg3140gbbb ... Show all