Duct Locations
without a Wall Oven
Cooktops can be vented vertically or horizontally.
If vented horizontally vent air through left or rear wall.
If vented vertically, locate hole between floor joists.
Do not vent exhaust air into a wall, ceiling, or a
Concealed space of a building.
Back Edge of
Cooktop Cutout
Cooktop
Side View
Cooktop
Front View
f-' !"'
"'
_ ''"
_ _' ''
_''''
_ _ ' _ ""_4"
fl _ ' " ' ' ' " " J ' " " ' J ' " " " J " ' " ;' "r_4"
t
_/"
[_
_..............
.t.
................
i
{÷6 1/2" -_i
*--6/8" _i
i
Duct Length Calculations
Ducting length is calculated in terms of straight
metal duct. Fittings such as elbows or transition
pieces should be limited to 50% of total duct length.
Using too many fittings can cause airflow problems.
Maximum allowable calculated duct length is 60
equivalent feet.
Use Duct Length Piece Equivalents section
found in the Installation Instructions.
Do not use any duct other than metal.
Flexible duct is not recommended because it
can create a fire hazard. However, if it is used,
one foot of flexible duct is equal to two feet of
smooth metal duct.
Exterior exhaust opening must be a minimum of
one foot (12 inches) from an obstruction.
1' of Duct
1'
90° Elbow
5'
3' of Duct
3'
",
90° Elbow
5'
-_
10' of Duct
10' -2
TotalFeet
24'
"-
Amana's ongoing commitment to quality products may mean a change in product specifications without notice.