Download Print this page
Amana ACC6356KF Installation Instructions
Amana ACC6356KF Installation Instructions

Amana ACC6356KF Installation Instructions

Electric built-in cooktop

Advertisement

Quick Links

PRODUCT MODEL NUMBERS
ACC6356KF
Electrical:
If codes permit and a separate ground wire is used, it is recommended that a
qualified electrical installer determine that the ground path and wire gauge are in
accordance with local codes.
Check with a qualified electrical installer if you are not sure the cooktop is
properly grounded.
Before You Make the Electrical Connection:
To properly install your cooktop, you must determine the type of electrical
connection you will be using and follow the instructions provided for it here.
A 4-wire or 3-wire, single phase, 240 volt, 60 Hz., AC only electrical supply is
required on a separate, 40-amp circuit, fused on both sides of the line. The
model/serial number rating plate is located on the metal cabinet underneath
the cooktop. See the following illustration.
A. Model/serial number plate
Cooktops with 3-wire cable coming from the cooktop are rated 240 volt
and do not have a neutral (white) wire.
The cooktop should be connected directly to the junction box through flexible,
armored or nonmetallic sheathed, copper cable. The flexible, armored cable
extending from the fuse box or circuit breaker box should
be connected directly to the junction box.
Locate the junction box to allow as much slack as possible between the
junction box and the cooktop so that the cooktop can be moved if servicing
becomes necessary in the future.
Do not cut the conduit. The length of conduit provided is for serviceability
of the cooktop.
A UL listed or CSA approved conduit connector must be provided at each end
of the power supply cable (at the cooktop and at the junction box). A listed
conduit connector is already provided at the cooktop.
If the house has aluminum wiring follow the procedure below:
1. Connect a section of solid copper wire to the pigtail leads.
2. Connect the aluminum wiring to the added section of copper wire
using special connectors and/or tools designed and UL listed for
joining copper to aluminum.
Follow the electrical connector manufacturer's recommended procedure.
Aluminum/copper connection must conform with local codes and industry
accepted wiring practices.
Electrical Connection Options
If your home has:
And you will be
connecting to:
4-wire
A fused disconnect or
circuit breaker box
5"
(12.7 cm)
3-wire
A fused disconnect or
circuit breaker box
1"
(2.5 cm)
3"
(7.6 cm)
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Electric Built-in Cooktop
A
Go to Section:
4-Wire Cable from Home
Power Supply
3-Wire Cable from Home
Power Supply
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
LOCATION REQUIREMENTS
IMPORTANT: Observe all governing codes and ordinances. When installing cooktop, use
minimum dimensions given.
To eliminate the risk of burns or fire by reaching over the heated surface units, cabinet storage
space located above the surface units should be avoided. If cabinet storage is to be provided,
the risk can be reduced by installing a range hood that projects horizontally a minimum of 5"
(12.7 cm) beyond the bottom of the cabinets.
The cooktop must be a specified cooktop that is approved to be installed either alone or
over an undercounter built-in oven. Check the cooktop base approved installation label for
your cooktop model number and approved combinations of cooktops and ovens that can
be installed. If you do not find this label, your cooktop may not be approved for use over an
undercounter built-in oven. Contact your dealer to confirm that your cooktop is approved.
Ovens approved for this type of installation will have an approval label located on the top of the
oven. If you do not find this label, contact your dealer to confirm that your oven is approved.
Refer to oven manufacturer's Installation Instructions for approval for built-in undercounter use
and proper cutout dimensions.
When installing cooktop over an undercounter built-in oven, do not fasten cooktop to countertop
with screws. This will make the cooktop easier to remove if future servicing becomes necessary.
Use the countertop opening dimensions that are given with these Installation Instructions. Given
dimensions are minimum clearances and provide 0" (0 cm) clearance.
Grounded electrical supply is required. See "Electrical Requirements" section.
IMPORTANT: To avoid damage, check with your builder or cabinet supplier to make sure that the
materials used will not discolor, delaminate or sustain other damage.

PRODUCT DIMENSIONS

A
A. 21" (53.3 cm)
B. 30" (76.2 cm)
C. 3¼" (8.3 cm)
CABINET OPENING DIMENSIONS
IMPORTANT: If installing a
range hood or microwave
hood combination above the
cooktop, follow the range hood
or microwave hood combination
installation instructions for
dimensional clearances above the
cooktop surface.
A. 30" (76.2 cm) models on 30"
(76.2 cm) models; 36" (91.4
cm) on 36" (91.4 cm) models
B. Combustible area above
countertop (shown by
dashed box above)
C. 30" (76.2 cm) minimum
clearance between top
of cooktop platform and
bottom of uncovered wood
or metal cabinet (24" [61
cm] minimum clearance if
bottom of wood or metal
cabinet is covered by not
less than
/
" [0.6 cm] flame
1
4
retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015" [0.04
cm] stainless steel or 0.024" [0.06 cm] aluminum or 0.020" [0.05 cm] copper)
D. 13" (33 cm) recommended upper cabinet depth
E. 3" (7.6 cm)
F. 19
/
" (50.3 cm)
13
16
G. 18" (45.7 cm) minimum clearance from upper cabinet to countertop within minimum
horizontal clearances to cooktop
H. Junction box or outlet; 12" (30.5 cm) minimum from bottom of countertop
I.
Junction box or outlet; 10" (25.4 cm) from right side of cabinet
J. 28
5
/
" (71.9 cm) on 30" (76.2 cm) ; 34
16
K. 1" (2.5 cm) minimum distance to nearest left and right side combustible surface
above cooktop
L. 1" (2.5 cm) minimum clearance between back wall and countertop
B
36" (91.4 cm)
A
B
C
L
F
E
H
I
K
J
7
/
" (88.6 cm) on 36" (91.4 cm) models
8
C
D
G
Ref. W10274252A
3/16

Advertisement

loading