350 s
11. f
e
ire
xTinguishing
Your 350 Sundancer has an automatic fire
extinguisher system installed standard. Refer to
the General Information Sections for a detailed
explanation of the automatic fire extinguisher
system.
12. f
s
uel
YsTeM
a. g
f
s
asoline
uel
YsTeM
The standard gasoline fuel system on your 350SDA
consists of a 225 gal. (852 liter) fuel tank, fuel tank
vent, electronic fuel sender, anti-siphon valve,
engine fuel supply line and fuel fill.
The optional twin engine gasoline fuel system uses
a single tank with two electronic fuel senders, anti-
siphon valves and engine fuel supply lines.
f
s
(g
s
uel
ysTem
as
(f
. 17.1)
Ig
PORT
350 Sundancer
undancer
s
YsTeM
d
- s
Tern
rIve
HoWn WITH
FUEL FILL
HOSES
FUEL VENT
HOSES
FUEL TANK
o
m
®
Wners
b. D
f
s
iesel
uel
The optional diesel fuel system consists of a 225
gal. (852 liter) fuel tank, fuel tank vents, engine fuel
supply and return lines, fuel filter and fuel fill.
13. W
s
aTer
The fresh water system on the 350SDA consists
of a 40 gal. (151 liter) tank. Refer to the General
Information Sections for a detailed explanation of
the water system.
g
o
)
eneraTor
PTIon
GENERATOR
FUEL VALVE &
FILTER (OPT)
ELECTRIC
FUEL VALVES
GENERATOR
FUEL FEED
(OPT)
anual
(o
)
YsTeM
pTional
YsTeM
STARBOARD
ENGINE FUEL
FEED
17