This thermostat is a wall mounted, low-voltage thermostat
which maintains room temperature by controlling the operation
of a heating and air conditioning system. Batteries are not
required; temperature and mode settings are preserved with
the power off. This communicating thermostat communicates
via a 4-wire Modbus protocol and will only operate with the
IntelliZone2 and Aurora AXB.

Thermostat Operation

Time
Heating Set
Point
Cooling
Set Point
Outdoor temperature is only displayed if an outdoor
NOTE:
sensor is installed.
To select a MODE, press the screen button MODE, and then
press the desired operating mode.
OFF
HEAT
COOL
AUTO (heat and cool as needed)
E-HEAT
*IG1605EW*
IG1605EW
06/15
USER GUIDE: INTELLIZONE2 MASTERSTAT COMMUNICATING THERMOSTAT
Date
Zone Displayed
Outside
Temperature
Room
Temperature
Room Humidity
Mode &
Comp SPD

Fan Operation

Error Code
Adjusting Temperature
(Temporary Override in Programmable models)
Press the blue up or down arrow to increase or decrease the
cooling temperature set point. Press the red up or down arrow
to increase or decrease the heating temperature set point.
Depending on the selected mode one or both sets of the
up/down arrows will be selectable.
If a programmed schedule is active, the cancel button in
the lower left hand corner of the screen will show up when
temperature or mode selections are made. Select the button to
cancel any changes that were made.
Menu
Press the Menu button.
NOTE: The humidity function must be enabled by the installer
for it to display on this screen. If your system does not use a
humidifier this function may not be enabled.
Fan Operation
The thermostat can operate the fan in three ways:
AUTO (on only during heating and cooling
operation) (DEFAULT)
CONTINUOUS (always on)
INTERMITTENT (cycles fan)
From the Home screen or Menu Screen, press the Fan button.
Select the operation you desire as described above by pressing
the up and down arrows ▲▼.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IntelliZone2 MasterStat and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Water Furnace IntelliZone2 MasterStat

  • Page 1: User Guide

    User Guide: USER GUIDE: INTELLIZONE2 MASTERSTAT COMMUNICATING THERMOSTAT IntelliZone2 MasterStat System Communicating with Humidity Control Thermostat Adjusting Temperature (Temporary Override in Programmable models) Press the blue up or down arrow to increase or decrease the cooling temperature set point. Press the red up or down arrow to increase or decrease the heating temperature set point.
  • Page 2: Programming Your Thermostat

    USER GUIDE: INTELLIZONE2 MASTERSTAT COMMUNICATING THERMOSTAT Intermittent Fan Zone Temperature conditions can vary widely between the thermostat This screen shows the status of the IntelliZone2 system on location and the extremities of the space the thermostat serves. one screen. Displayed information includes zone size, priority,...
  • Page 3 USER GUIDE: INTELLIZONE2 MASTERSTAT COMMUNICATING THERMOSTAT Programming a Day or a Series Of Days Security Lockout This thermostat has the option to set security features to lockout After selecting the programming screen, you have the option everything but the adjustment of the temperature.
  • Page 4 USER GUIDE: INTELLIZONE2 MASTERSTAT COMMUNICATING THERMOSTAT Vacation On Peak (If Installed) From the MENU, press the Vacation button to set vacation The ‘On Peak’ input is designed to allow utilities to utilize starting date, time, and desired temperature, return date, time.
  • Page 5 USER GUIDE: INTELLIZONE2 MASTERSTAT COMMUNICATING THERMOSTAT Monthly Energy Use screen Monitor AWL Status - When enabled, the thermostat will monitor the AWL’s RS485, INTERNET, and SERVER status. The thermostat will display “AWL Comm Err” when the AWL is not communicating properly with the Aurora Modbus Network, “AWL Internet Err”...
  • Page 6 USER GUIDE: INTELLIZONE2 MASTERSTAT COMMUNICATING THERMOSTAT - When Heating mode is active the triangle Heat Mode Display ZoneStat User Information next to the HEAT icon is flashing. The HOLD icon is energized if a temperature override or a fan override is active. A temperature override is set if the set point is adjusted from the schedule set point in programmable mode.
  • Page 8 ©2015 WaterFurnace International, Inc., 9000 Conservation Way, Fort Wayne, IN 46809-9794. WaterFurnace has a policy of continual product research and development and reserves the right to change design and specifi cations without notice. *IG1605EW* IG1605EW 06/15...

Table of Contents

Save PDF