Winterizing and long-term storage
If you must store your pressure washer in a location where
the temperature falls below 32ºF (0ºC), you can minimize the
chance of damage to your machine by utilizing the following
procedure:
• Disconnect all water connections.
• Turn on the machine for a few seconds until the remaining
water in the pump exits. Turn off immediately.
• Do not allow the high-pressure hose to become kinked.
• Store the machine and accessories in a room that does
not reach freezing temperatures.
• Do not store near a furnace or other sources of heat that
may dry out the pump seals.
• Operate the pressure washer with non-corrosive/non-toxic
anti-freeze, a pump saver, or a pump protector before
storing for the winter.
m
WARNING!
Before reusing, completely flush the unit
out with clear water. Anti-freeze products can damage
paintwork, so you must ensure there is no anti-freeze left in the
system before using it again.
Maintenance
m
CAUTION!
Before working on the pressure washer,
disconnect the plug from the power supply socket.
1. To ensure good performance, check and clean the water
inlet filter (Fig. 27). Remove the filter and rinse with warm
water to prevent any foreign matter from clogging the
pump (Fig. 28).
Fig. 27
(FRONT)
Water inlet filter
Garden hose adaptor
!
Fig. 28
Inlet filter
2. Clean the nozzle with the needle clean-out tool provided
(Fig. 29). Remove the spray wand from the gun; remove
any dirt from the nozzle hole and rinse.
Fig. 29
3. Remove additional debris by back flushing water through
the nozzle and spray wand. To do this, place the end of
your garden hose (with water running) to the tip of the
nozzle, pushing water and debris out of the back opening
of the nozzle and spray wand.
Circuit Diagram
A circuit diagram for the pressure washer is provided below for
your reference (Fig. 30).
Fig. 30
Micro-switch
Motor
Capacitor
13
Needle clean-out tool
Power cord
On/off switch