Installation Instructions
Honeywell Air Sampling Smoke Detection System
Honeywell HI-SPEC
10
9
5
7
8
4
1
Operating-indicator light
2
Indicator light for fault
3
Indicator light for alert alarm-detector module I
4
Indicator light for action alarm-detector module I
5
Indicator light for fire alarm-detector module I
6
Smoke level display 1 to 10 for detector module I
7
Indicator light for alert alarm-detector module II
8
Indicator light for action alarm-detector module II
9
Indicator light for fire alarm-detector module II
10
Smoke level display 1 to 10 for detector module II
11
Pre-punched cable entries for connection to the central fire panel or power supply (input/output)
12
Connection pipe system I
13
Connection pipe system II
14
Connection for air return
HI-SPEC unit_HON.doc
6
1
2
3
12
11
07/2011
13
11
14
11
1 of 12

Advertisement

loading

Summary of Contents for Honeywell HI-SPEC

  • Page 1 Installation Instructions Honeywell Air Sampling Smoke Detection System Honeywell HI-SPEC Operating-indicator light Indicator light for fault Indicator light for alert alarm-detector module I Indicator light for action alarm-detector module I Indicator light for fire alarm-detector module I Smoke level display 1 to 10 for detector module I...
  • Page 2: Installation Of The Detector Module

    Connect the detector module via the ribbon cable with the connection “Head 1” (detector module I) or “Head 2” (detector module II) to the base board. Note the labelling of the base board. Reconnect the display board to the base board (connection “Display”). Note the labelling of the base board. HI-SPEC unit_HON.doc 07/2011 2 of 12...
  • Page 3 Setting the delay “air flow fault” S1. 7 S1. 8 0.5 minutes 2 minutes 15 minutes 60 minutes Setting the fault signal S1. 9 non-latched latched ⋅ SENS Setting LOGIC S1.10 HI-SPEC unit_HON.doc 07/2011 3 of 12...
  • Page 4 The standard settings have a grey background. Setting the ventilator voltage base- additional board board Jumper BR 3 BR 1 BR 2 Pin No. 1 + 2 1 + 2 1 + 2 6,5 V 6,9 V HI-SPEC unit_HON.doc 07/2011 4 of 12...
  • Page 5 The following table shows the positioning of the jumpers: X = pin pair bridge O = pin pair open The standard settings have a grey background. Setting the collective fault contact Jumper JU7/8 JU7/8 Pin No. break contact make contact HI-SPEC unit_HON.doc 07/2011 5 of 12...
  • Page 6 O = pin pair open The standard settings have a grey background. Setting the alarm contacts Jumper JU1-6 JU1-6 Pin-No. break contact make contact Device Supports Support Type MT-1 horizontal installation Support Type MT-1 vertical installation HI-SPEC unit_HON.doc 07/2011 6 of 12...
  • Page 7: Installation Of The Device

    5. Pass the connection cable(s) (max. 1.5 mm²) required to wire the device through the prepared M20 or M25 glands into the device and cut it to the required length within the device. 6. Wire the device according to the following connection diagram. HI-SPEC unit_HON.doc 07/2011 7 of 12...
  • Page 8 24V für Display Parallel- anzeige Display Data +24V +24V +24V Alt.Sens. +24V +24V Reset +24V HI-SPEC unit_HON.doc 07/2011 8 of 12...
  • Page 9 X5 / 1 + input line “Fault II“ X5 / 2 - input line “Fault II” X5 / 3 + input line “Alert alarm II“ X5 / 4 - input line “Alert alarm II” HI-SPEC unit_HON.doc 07/2011 9 of 12...
  • Page 10 X10 / 4 0 V supply voltage X11 / 1 + data external Display X11 / 2 - data external Display X12 / 1 + 24 V external Display X12 / 2 0 V external Display HI-SPEC unit_HON.doc 07/2011 10 of 12...
  • Page 11 4. During and after initialization the pipe system must no longer be changed. Even the ventilator voltage of the device must no longer be modified after initializations. Otherwise the initialization must be carried out again. HI-SPEC unit_HON.doc 07/2011 11 of 12...
  • Page 12 Class: A, B and C 0,1 % light obscuration/m Class: A, B and C 0,5 % light obscuration/m Class: A, B and C Honeywell Life Safety Systems 140 Waterside Road Hamilton Industrial Park Leicester LE5 1TN (+44) 116 246 2000 HI-SPEC unit_HON.doc...