AT commands: Detailed description
AT=x
The register number n and register value x are returned as a numerical ASCII
string. The valid values for x may be restricted (see register S0, for example).
Please refer to chapter "Description of registers" for information about the S
register and changing bit-oriented registers. If a register is set to an invalid
value the command is ignored and returns ERROR. If an invalid setting is
made in a bit-oriented register, only that particular setting will be ignored; all
other valid bits will be accepted.
\T
Inactivity timer
AT\Tn : (n = 0..255 * 10 seconds; default value = 0)
This command can be used to control the period of time after which the
MicroLink ISDN i automatically breaks the connection if no data has been
sent in the mean time. The default value 0 switches the inactivity timer off.
$UPX
Firmware upload in flash ROM
AT$UPX
New firmware can be loaded to the flash ROM using the command AT$UPX.
After issuing the command, the firmware file must be sent to the MicroLink
ISDN i using the XModem protocol. The firmware file can be found on the CD
which was included with the unit. The current version can be found in our
online services www.devolo.de.
V
Messages in short form/plain text
ATV0
*ATV1
This command can be used to select numerical short form or plain text for the
messages sent by the MicroLink ISDN i to the attached computer. The mes-
sages in short form and plain text are covered in the chapter "Description of
messages".
|
devolo MicroLink ISDN i
|
: Sets the value of last register used to x
: Messages in short form as a digit
: Messages in plain text
|