ANALOG MULTITESTER
INSTRUCTION MANUAL
KF-20
FOR SAFETY MEASUREMENTS!!
To prevent an electrical shock hazard to the operator and/or damage to the
instruments, read this instruction manual carefully before using the
Multitester. WARNINGS with the symbol
on the Multitester and this
instruction manual are highly important.
Important Symbols
The symbol listed in IEC 61010-1 and ISO 3864 means "Caution
(refer to instruction manual)".
WARNING : The symbol in this manual advises the user of an
electrical shock hazard that could result in serious injury or even
death.
CAUTION : The symbol in this manual advises the user of an
electrical shock hazard that could cause injury or material damages.
WARNING
Do not measure High Power Line that might exceed 2kVA. Measurement on
High Power Line is very dangerous. It sometimes includes High Surge
Voltage that could cause dangerous arcs of explosive short in the instrument
and could result in serious injury to the operator. When measuring high
voltage, even for Low Power Line (Low Energy Circuit), take extra care to
avoid electrical shock hazard and/or damage to the instrument.
INTRODUCTION
Thank you for purchasing KAISE "MODEL KF-20 ANALOG MULTITESTER". To
obtain the maximum performance of this instrument, read this Instruction Manual
carefully, and take safe measurement.
1. UNPACKING AND INSPECTIONS
Inspect the instrument and acessories for transport damage. If there is any
damage or missing items, ask your local dealer for replacement.
Confirm that the following items are contained in the package.
1. Analog Multitester
1 pce.
2. Test Lead (100-51)
1 set
3. Holster
1 pce.
4. Spare Battery (1.5V R6P)
1 pce.
5. Instruction Manual
1 pce.
2. SPECIFICATIONS
2-1. MEASUREMENT SPECIFICATIONS
DC Voltage ( DC-V )
0.3 / 3 / 12 / 30 / 120 / 300 / 1200V
AC Voltage ( AC-V )
12 / 30 / 120 / 300 / 1200V
60 A / 3mA / 30mA / 300mA
μ
DC Current ( DC-mA )
Resistance ( Ω )
5KΩ / 500KΩ / 5MΩ
1.5V Battery Test
1.5V R20P / R14P / R6P
1.5V 250mA
Hi Range
Lo Range
1.5V
50mA
−50℃∼+250℃
Temperature ( ℃ )
1
2-2. GENERAL SPECIFICATIONS
DC : ±3% f.s., AC : ±4% f.s.
Accuracy
Ω / TEMP : ±3% f.s.length
×1 and 300mA range : protected by internal diode
Overload Protection
and 0.3A / 250V fuse
1.5V R6P (AA) battery ×1
Power Supply
Dimensions & Weight
136(H)×90(W)×30 (D)mm, 215g
100-51 Test Lead ×1 set
Holster ×1
Accessories
1.5V R6P (AA) Battery (built-in and spare) ×1 each
Spare Fuse (0.3A/250V)×1 (inside the rear case)
Instruction Manual
660 Clamp Adapter
810-02 Temperature Probe
Optional Accessories
940 Alligator Clip
3. SAFETY PRECAUTIONS
Correct knowledge of electric measurements is essential to avoid unexpected
danger such as operator's injury or damage to the instrument. Read carefully and
observe the following precautions for safety measurements.
3-1. WARNINGS
WARNING 1. Checks of Body and Test Lead
Before measurement, confirm the body of this instrument and handle insulators of
the Test Lead have no cracks or any other damages. Dust, grease and moisture
must be removed.
WARNING 2. High Power Line Measurements Prohibited
This instrument is applicable for Low Energy Circuit measurements only.
Do not use for High Power Line (High Energy Circuit) measurements such as
Distribution Transformers, Bus Bars and Large Motors.
WARNING 3. Warning for High Voltage Measurements
Even for Low Energy Circuits of electric/electronic appliances, such as heating
elements, small motors, line cords and plugs, High Voltage Measurements are
very dangerous. Do not touch Multitester, Test Leads, and any part of the circuit.
Generally, shock hazard could occur when the current between the circuit, that
involves more than 33V rms or 46.7V DC or peak, and ground goes up to 0.5mA
or more.
WARNING 4. Dangerous Voltage Measurement Procedures
For dangerous voltage measurement, strictly observe the warnings below.
(refer to fig.1)
Turn off the circuit to be measured.
1.
2.
Plug black test lead to "- (COM)" terminal and red test lead into "+" terminal.
3.
Attach black and red alligator clips to test lead pins.
Set RANGE Switch to desired DC or AC voltage range.
4.
5.
Connect black alligator clip to - (earth) side and red alligator clip to + (positive)
side of the measuring circuit.
6.
Do not hold Multitester and test leads in your hands. Keep safety distance
from power source or circuit to be measured not to touch the dangerous
voltage.
7.
Turn on the circuit to be measured, and read the meter.
8.
Turn off the circuit again. Detach alligator clips after confirming the meter
returns into "0".
KF-20
30
15
6
3
DC
DC
AC
AC
TEMP
TEMP
BATT
℃
BATT
1.5V VOLT
TAUT BAND
20,000/V DC
DROP
10,000/V AC
PROOF
PROTECTION
Red
Allligator
Black
MADE IN JAPAN
NO.
Test Lead
Clip
Ω
TEMP
Test Lead
1200
×
1
×
100
×
1k
1200
AC-V
DC-V
300
300
120
120
30
30
12
12
Hi
3
Lo
60
μ
3
30 300
BAT.
0.3
DC
A
C O M
m
In case of live-line measurement, strictly observe the warnings
below (refer to fig 2.)
Set RANGE Switch to desired DC or AC voltage range.
1.
Attach alligator clip to black test lead pin, and connect to - (earth) side of the
2.
measuring circuit.
Do not hold Multitester in your hands. Keep safety distance from power source
3.
or circuit to be measured not to touch the dangerous voltage.
4.
Connect red test lead to + (positive) side, and read the meter.
Detach red test lead from the circuit first, then detach black alligator clip.
5.
2
KF-20
30
15
6
3
DC
DC
AC
AC
TEMP
TEMP
℃
BATT
BATT
1.5V VOLT
TAUT BAND
20,000/V DC
DROP
10,000/V AC
PROOF
PROTECTION
Black
MADE IN JAPAN
NO.
Ω
TEMP
Test Lead
1200
×
1
×
100
×
1k
1200
AC-V
DC-V
300
300
120
120
30
30
12
12
Hi
3
Lo
3
30 300
0.3
60
μ
BAT.
DC
m
A
C O M
WARNING 5. Correct Selection of RANGE Switch
Always confirm that RANGE Switch is set to the correct position. Do not measure
voltage in DC-mA, Ω and BAT. ranges.
KF-20
30
15
6
3
DC
DC
AC
AC
TEMP
TEMP
℃
BATT
BATT
1.5V VOLT
TAUT BAND
20,000/V DC
DROP
10,000/V AC
PROOF
PROTECTION
MADE IN JAPAN
NO.
Ω
TEMP
1200
×
1
×
100
×
1k
1200
AC-V
DC-V
300
300
120
120
30
30
12
12
Hi
3
Lo
60
μ
3
30 300
BAT.
0.3
DC
m
A
C O M
when measuring DC. mA /Ωrange
WARNING 6. Maximum Measurement Range Observance
Measurement exceeding the specified maximum values of each measurement
range is prohibited.
WARNING 7. Test Lead Detachment
Detach test leads from the measuring circuit before rotating RANGE Switch or
opening rear case for battery or fuse replacement.
3-2. GENERAL WARNINGS AND CAUTIONS
WARNING 1.
Children and the persons who do not have enough knowledge
about electric measurements must not use this instrument.
WARNING 2.
Do not measure the electricity naked or barefooted to protect
yourself from electrical shock hazard.
WARNING 3.
Be careful not to get hurt with the sharp test lead pins.
CAUTION 1.
Do not polish the case or attempt to clean it with any cleansing
fluid like gasoline or benzine. If necessary, use silicon oil or
antistatic fluid.
CAUTION 2.
Avoid the multitester from hard mechanical shock or vibration,
high temperature and strong magnetic field.
CAUTION 3.
Remove the batteries when the multitester is out of use for a
long time. The exhausted batteries might leak electrolyte and
corrode the inside.
4. NAME ILLUSTRATION
KF-20
Meter Case
30
15
6
3
DC
DC
AC
AC
Pointer
TEMP
TEMP
℃
BATT
BATT
1.5V VOLT
20,000/V DC
DROP
10,000/V AC
PROOF
PROTECTION
Zero Adjustment
MADE IN JAPAN
NO.
Screw
Ω
TEMP
1k
1200
1200
×
1
×
100
×
DC-V
AC-V
300
300
120
120
fig. 1
RANGE Switch
30
30
12
12
Hi
3
Lo
30 300
60
μ
3
BAT.
0.3
DC
m
A
C O M
100-51 Test Lead
3
5. MEASUREMENT PROCEDURES
5-1. PREPARATION FOR USE
Red
Test Lead
1. INSTRUCTION MANUAL
Read INSTRUCTION MANUAL carefully to understand the specification and
Allligator
functions correctly. 「3. SAFETY PRECAUTIONS」is higly important for safety
Clip
measurement.
2. BATTERY
KF-20 contains 1 x 1.5V R6P (AA) battery. Replace it referring to 「6-1.
BATTERY REPLACEMENT」when exhausted.
fig. 2
3. FUSE
KF-20 contains 1 x fast-acting 0.3A/250V (φ5x20mm) fuse to protect Resistance
and Current measurement ranges. For replacement, refer to 「6-2. FUSE
REPLACEMENT」.
4. ZERO ADJUSTMENT
outlet
Before measurement, confirm that meter points to "0". If not, adjust the pointer by
×
Zero Adjustment Screw to take accurate measurement.
5. TEST LEAD
Insert black test lead into - (COM) terminal, and red test lead into + terminal.
6. RANGE SWITCH
(1) Range Selection
a.
Set the switch to a desired measurement range.
To measure uncertain voltage or current, firstly measure the approximate
value at the highest range, then change the switch into the suitable range.
b.
For correct voltage and current measurements, select the range to point the
right side of the meter scale. (between center scale and maximum scale)
fig. 3
c.
For correct resistance measurement, select the range to point around the
center of OHMS scale.
(2) Confirmation of the Range
Always confirm that RANGE Switch is set to the proper measurement range. To
avoid serious damage to the instrument, do not measure voltage in DC-mA, Ω
and BAT ranges.
WARNING
Detach test leads from the circuit before rotating RANGE Switch to avoid electric
shock hazard and serious damage to the instrument.
7. Meter Scale Reading
UCHIDA
DC
AC
TEMP
BATT
20,000/V DC
10,000/V AC
PROTECTION
DC/AC scale
(for AC/DC Voltage, DC Current measurements : V, μA, mA)
Select suitable scale from "0 - 6", "0 - 12", or "0 - 30" applying certain multiple.
Reading examples :
DC 0.3V range : Read "0 - 30" scale multiplying by 1/100.
DC 120V range : Read "0 - 12" scale multiplying by 10.
DC 60uA range : Read "0 - 6" scale multiplying by 10.
Rear Case
DC 300mA range : Read "0 - 30" scale multiplying by 10.
(for Resistance measurement : Ω)
OHM scale
Meter Scale
Multiply the scale value depending on the measurement range.
Reading examples :
"x 1" range : Read the scale directly.
"x 100" range : Multiply the scale value by 100.
0ΩADJ. Knob
"x 1k" range : Multiply the scale value by 1,000.
TEMP scale (for Temperature measurement : ℃)
+Terminal
Read the scale directly.
−(COM)
Terminal
8. Measurement Accuracy
For accurate measurement, read following notes carefully.
Before measurement, confirm that meter points to "0". (zero-adjusted)
1.
Select proper range referring to 「5-1. 6-(1) Range Selection」.
2.
3.
Read the meter from directly over the pointer.
Measurement in strong magnetic field or on iron plate causes reading error or
4.
meter sensitivity wrong.
5.
Once-a-year periodical calibration is necessary to maintain tolerance accuracy
and to take safety measurements.
fig. 4
30
OHMS scale
15
6
DC/AC scale
3
DC
AC
TEMP
℃
BATT
TEMP scale
1.5V VOLT
TAUT BAND
DROP
PROOF
BATT scale
NO.
fig. 5
4
Need help?
Do you have a question about the KF-20 and is the answer not in the manual?
Questions and answers