Operating Tips
Purge air out of ALL hot and cold water lines.
Open the water heater door and turn the power switch "ON".
Set GMC dial to appropriate setting.
Open hot water faucet to a medium water flow.
To reduce temperature:
o
o
o
To increase temperature:
o
o
For Additional Information
For detailed operating information refer to the manufacturer's owner's manual
included in the Warranty Packet.
Winterization
Freezing of the water heater and its plumbing components will result in severe
damage not covered by warranty. For this reason it is advisable to follow the
recommendation(s) below if the unit is to be stored in a freezing environment or for
long periods of time. At the start of the winter season or before traveling to a
location where freezing conditions are likely, the unit must be winterized.
The very small amount of water present in the heat exchanger DOES NOT require
the installation of a bypass kit.
the two common methods of winterization used for RV water systems, The
compressed air method or the anti-freeze method. Refer to "Winterization" in this
section for details.
Winter Use Device (WUD)
If you wish to operate the water heater in potentially freezing conditions the model
GSWH-1M has a built in thermostat that will start the burner whenever the
temperature of the Heat Exchanger falls below 38ºF and will automatically shut off
when it senses a temperature in excess of 58 ºF.
IMPORTANT: To allow the WUD device to operate you must have sufficient LP
Gas in the tank and you must leave the unit powered with the ON / OFF switch in
the ON position at all times that freezing may occur. It will not protect the entire
RV's plumbing system. The RV must be designed for winter use/freezing
conditions.
Pressure - Temperature Relief Valve
This water heater is equipped with a temperature and pressure relief valve that
complies with the standard for Relief Valves and Automatic Gas Shutoff Devices
for Hot Water Systems, ANSI Z21.22.
Valve is not serviceable; if defective it must be replaced.
Tampering with valve will result in scalding injury. Do not place a plug or
reducing coupling on outlet part of valve. If you use a discharge line
allow complete drainage for both valve and line.
Tampering with valve will void the warranty.
8-8
Turn GMC dial "counter-clockwise".
Increase hot water flow.
Gradually add cold water.
Turn GMC dial "clockwise".
Reduce hot water flow.
Winterization can be accomplished using one of
SCALDING INJURY-EXPLOSION
JAYCO CLASS A MOTOR HOMES
WARNING

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

2015 precept

Table of Contents