Aiwa XP-V410 Service Manual page 33

Hide thumbs Also See for XP-V410:
Table of Contents

Advertisement

3. Confirmation of Sled movement
By pressing the F.SKIP or B.SKIP button continuously during the TEST MODE, it is possible to transfer the pick-up to either the outer
side or inner side.
4. Confirmation of the RF level
Test point: RF and VC (Vref)
Test disc: TCD-782
Confirm that the RF waveform is as shown below.
5. Confirmation of Tracking balance
Test point: TE and VC (Vref)
Test disc: TCD-782
Press the DSL button while playing the test disc and confirm the TE waveform is as shown below.
6. Confirmation of each servo
It is possible to confirm the adjustment value of each servo by repeatedly pressing the MODE button while the disc is playing.
The switchover sequence is as stated below.
Confirmation mode off ™ Focus Bias (FB) ™ Tracking Balance (TB) ™ Tracking Gain (TG) ™ Tracking Error Offset (TEO) ™
Focus Gain (FG) ™ Focus Error Offset (FEO) ™ Confirmation mode off
Example: Tracking Error Offset (TEO) Adjustment value: 03
te
Tracking Error Offset (TEO) display
* Adjustment value is displayed in HEX.
0.8Vp-p or more
VOLT/DIV: 200mV
TIME/DIV: 0.5us
A
VC
A:B=1:1
B
VOLT/DIV: 200mV
TIME/DIV: 2ms
0
:03
Adjustment value
15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xp-v411Xp-v416cXp-v4116cXp-v4116calhXp-v4116calhs

Table of Contents