Majestic fireplaces 33LDVR Installation Instructions And Homeowner's Manual
Majestic fireplaces 33LDVR Installation Instructions And Homeowner's Manual

Majestic fireplaces 33LDVR Installation Instructions And Homeowner's Manual

Builder rear vent direct vent

Advertisement

INSTALLER/CONSUMER
SAFETY INFORMATION
PLEASE READ THIS MANUAL
BEFORE INSTALLING AND
USING APPLIANCE
WARNING!
IF THE INFORMATION IN THIS
MANUAL IS NOT FOLLOWED
EXACTLY, A FIRE OR EXPLO-
SION MAY RESULT CAUSING
PROPERTY DAMAGE, PER-
SONAL INJURY OR LOSS OF
LIFE.
FOR YOUR SAFETY
Installation and service must
be performed by a qualified
installer, service agency or
the gas supplier.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electric switch;
do not use any phone in your
building.
Immediately call your gas
supplier from your neighborʼs
phone. Follow the gas suppliers
instructions.
If you cannot reach your gas
supplier call the fire department.
DO NOT STORE OR USE
GASOLINE OR OTHER
FLAMMABLE VAPORS AND
LIQUIDS IN THE VICINITY OF
THIS OR ANY OTHER
APPLIANCE.
INSTALLER: DO NOT DISCARD THIS MANUAL - LEAVE FOR HOMEOWNER
Builder Rear Vent
Direct Vent
Models: 33LDVR, 36LDVR,
� � �� � � � � �
39LDVR, 43LDVR
Installation Instructions and
Homeownerʼs Manual
7317
LDVR COVER
1/05
CFM Specialty Home Products
410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777
www.majesticproducts.com • www.vermontcastings.com
10007317 11/05 Rev. 4

Advertisement

Table of Contents
loading

Summary of Contents for Majestic fireplaces 33LDVR

  • Page 1 THIS OR ANY OTHER APPLIANCE. � � �� � � � � � INSTALLER: DO NOT DISCARD THIS MANUAL - LEAVE FOR HOMEOWNER Builder Rear Vent Direct Vent Models: 33LDVR, 36LDVR, 39LDVR, 43LDVR Installation Instructions and Homeownerʼs Manual 7317 LDVR COVER...
  • Page 2: Table Of Contents

    PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS Thank you and congratulations on your purchase of a CFM Specialty Home Products fireplace. IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions fully may result in a possible fire hazard and will void the warranty. Installation &...
  • Page 3: Installation & Operating Instructions

    Installation & Operating Instructions This gas appliance should be installed by a qualified installer in accordance with local building codes and with current CSA-B149.1 Installation codes for Gas Burning Appliances and Equipment. For USA Installations follow local codes and/or the current National Fuel Gas Code. ANSI Z223.1/NFPA 54.
  • Page 4: Fireplace Dimensions

    Voltage Access Gas Line Access Fig. 2 Fireplace specifications and framing dimensions. Ref. 33LDVR 33” (838 mm) 28⁷⁄₈” (733 mm) 31¹⁄₄” (794 mm) 18³⁄₈” (466 mm) 24⁷⁄₈” (632 mm) 11¹⁄₂” (292 mm) 14¹⁄₄” (362 mm) 19³⁄₄” (501 mm) 23¹⁄₄” (590 mm) 4³⁄₄”...
  • Page 5: Clearance To Combustibles

    Mantel from Top This appliance may be installed in an aftermarket permanently located, manufactured home or mobile 33LDVR home, where not prohibited by local codes. 16¹⁄₂” (419 mm) This appliance is only for use with the type of gas indicated 14¹⁄₂”...
  • Page 6: Framing And Finishing

    If a Trim Kit is going to be installed on the fireplace, the brick or tile will have to be installed flush with the edges of the fireplace. 33LDVR / 36LDVR / 39LDVR / 43LDVR Certified To ANSI Z21.88b-2003 / CSA 2.33b-2003...
  • Page 7: Gas Line Installation

    Gas Line Installation When purging the gas lines, the front win- dow frame assembly must be removed. The gas pipeline can be brought in through the rear of the appliance as well as the bottom. Knockouts are provided on the bottom behind the valve to allow for the gas pipe installation and testing of any gas connection.
  • Page 8: Eb-1 Electrical Box

    EB-1 Electrical Box The fireplace, when installed, must be electrically connected and grounded in accordance with local codes or, in the ab- sence of local codes, with the current CSA C22.1 Canadian Electrical Code. For USA installations follow local codes and the national electrical code ANSI/ NFPA No.
  • Page 9: General Venting

    CIRCUIT BOARD Fig. 9 SIT822 Valve with Synetek electronic control wiring diagram. Your fireplace is approved to be vented either through the side wall, or vertically through the roof. • Only CFM Corporation venting components specifi- cally approved and labelled for this fireplace may be used.
  • Page 10: General Venting Information-Termination Location

    General Venting Information - Termination Location VENT TERMINATION CFM145a A = Clearance above grade, veranda, porch, deck, or balcony B = Clearance to window or door that may be opened C = Clearance to permanently closed window D = Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2ʼ...
  • Page 11: General Information Assembling Vent Pipes

    Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors. Inside Corner Combustible 6"(152mm) Noncombustible 2"(50mm) Balcony - with no side wall Combustible & Noncombustible 12"(305mm) Fig. 10 Termination clearances. General Information Assembling Vent Pipes Canadian Installations: Venting system must be installed in accordance with the current CSA-B149.1 installation code.
  • Page 12: How To Use The Vent Graph

    Twist Lock Pipes When using CFM Corporation twist-lock pipe it is not necessary to use sealant on the joints. The only areas of the venting system that need to be sealed with high temperature silicone sealant are the collars on the fireplace and termination, and the sliding joint of any telescopic vent section used in the system.
  • Page 13 20" (508mm) Top View Straight Venting DVR584-600 20" Rear vent no elbows (508mm) Max. 2/99 djt 45° Top View REAR VENT-TOP VIEW Rear Vent Corner Installation Fig. 14 Rear vent applications, one 45° elbow. FP836 Rear Wall Installation Rear Vent-Top View Twist Lock Pipe 11/21/98 STEP 1...
  • Page 14: Vertical Sidewall Applications & Installation

    Zero Clearance Sleeve Fig. 17 Firestop and zero clearance sleeve in place. CFM133 DVR Series Typical corner install 2/26/01 sta Finished Wall Fig. 18 Side view of final unit location. FP1005 Rear Wall Vent Installations - Side View Vent Termination Flex Vent Pipe 1/25/00 djt Follow Steps 1 and 2 on Page 13.
  • Page 15 Horizontal plane means no vertical rise exists on this portion of the vent assembly. • The maximum horizontal vent run is 20 ft. (6.1m) when the vertical vent rise is 7¹⁄₂ ft. (2.3m). (Fig. 21) • The maximum number of 90° elbows per side wall installation is three (3).
  • Page 16 Vertical Sidewall Installation STEP 1 Locate vent opening on the wall. It may be necessary to first position the fireplace and measure to obtain hole location. Depending on whether the wall is combustible or noncombustible, cut opening to size. (Fig. 25) For combustible walls first frame in opening.
  • Page 17: Below Grade Installation

    Always install hori- zontal venting on a level plane. Fig. 28 Measure horizontal length including 2” overlap. CFM136 Rear Vent horizontal length High 2/26/01 sta Temperature Sealant Fig. 29 Apply high temperature sealant. STEP 6 CFM137 Rear Vent length Apply high temperature sealant to 4” (102 mm) and 7” 2/26/01 sta (178 mm) collars or the termination one inch away from the end.
  • Page 18: Vertical Through-The-Roof Applications & Installation

    Zero Clearance Sleeve (if required) Firestop 7” Pipe 24" (610mm) Minimum* *A minimum of 24” (608mm) vertical pipe must be installed when using 7TDVSNORK Kit. Fig. 31 Below grade installation. Do not back fill around snorkel. A clearance of at least 4” (102mm) must be BG400 maintained between the snorkel and the Below grade installation...
  • Page 19 Max. 8ʼ (2.4m) 45° 40ʼ (12m) Max. 8ʼ (2.4m) 45° Typical Offset Installation Fig. 34 Typical vertical roof applications. FP1021 Vertical Through-the-Roof Installation Typical vertical through the roof 1. Locate your fireplace. application 2. Plumb to center of the (4”) flue collar from ceiling 3/26/00 djt above and mark position.
  • Page 20 Roof 2ʼ Min. Roof Support Attic Insulation 40ʼ Shield (12m) Attic Insulation Joists Fig. 37 Typical straight-up installation. FP1022 Typical Straight Up Installation 1/26/00 djt Vent Termination Storm Collar Roof Flash- Joists Fig. 38 Minimum termination to roof clearance. FP1022 Min.
  • Page 21: Venting Components

    584A venting components rear vent term 4/6/99 djt 584B Vent components Starter Kit 2/25/99 djt 584C Vent components 584D 45 degree elbow Vent Components 2/25/99 djt 90 degree elbow 10/20/99 twistlock 584E 2/25/99 djt Venting Components 10/20/99 twist lock Telescope vent 584F 2/25/99 djt Venting Components...
  • Page 22: Operating Instructions

    Glass Information Only glass approved by CFM Specialty Home Products should be used on this fireplace. • The use of any non-approved replacement glass will void all product warranties. • Care must be taken to avoid breakage of the glass. •...
  • Page 23: Installation Of Logs, Lava Rock & Ember Material

    BD18 Front Left (A43) Fig. 41 Correct log placement for 33LDVR. 1. Place rear log (B135) on rear bracket (ensure log is seated properly to the bracket and located to the two pins), so it will not move from side to side and is firmly positioned on the bracket.
  • Page 24 Rear (B135) Front Left (B136) Front Center (B138) LG383 Fig. 42 Correct log placement for 36LDVR. 39LDVR 1. Place rear lob (BC14) on rear bracket (ensure log is LG383 centered and seated properly to the log support). 36LDVR logs 2. Place front left log (BC15). Use logʼs bottom hole to locate it onto the front support and just rest on top of 1/05 the rear log.
  • Page 25: Flame & Temperature Adjustment

    ������ ��� ����� ������ Turn clockwise to increase LG384 flame height Fig. 48 Correct burner flame appearance for 33LDVR. Turn clockwise to decrease flame height Fig. 49 Correct burner flame appearance for 36LDVR. LG415 Fig. 50 Correct burner flame appearance for 39LDVR.
  • Page 26: Lighting And Operating Instructions

    Lighting and Operating Instructions FOR YOUR SAFETY READ BEFORE LIGHTING WARNING:If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This heater has a pilot which must be lit manu- ally.
  • Page 27 Lighting and Operating Instructions For Fireplaces equipped with SIT822 Gas Valve (EN or EP) Warning: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury and loss of life. FOR YOUR SAFETY READ THE FOLLOWING WARNINGS A.
  • Page 28: Troubleshooting

    Remove Window Frame Assembly Before Service Work START Gas Supply On ▼ Pilot Lights With Piezo Ignitor ▼ Pilot Stays Lit ▼ Pilot Lights Main Burner ▼ SYSTEM OK Troubleshooting - Honeywell Millivolt Valve CHECK • Supply Line Hooked Up •...
  • Page 29 Normal Operation ON/OFF Switch Closed? Safe Start Check On? 0 Sec Purge Ignition Trial: 30 sec Spark ON Pilot Valve ON. Has Flame been Detected within 30 sec? Spark Off. Main Valve ON. Pilot Flame Continuously Monitored Pilot Flame Sense OK? ON/OFF Switch Opened? Pilot and Main Valve OFF? 0 sec Post Purge?
  • Page 30: Fuel Conversion Instructions

    Fuel Conversion Instructions The conversion of this appliance from one gas to another must be carried out by an authorized service provider. 1. Disconnect power to the unit and shut off the gas sup- ply. 2. Remove window frame assembly. 3.
  • Page 31: Maintenance

    Burner and Burner Compartment It is important to keep the burner and the burner compartment clean. At least once per year the logs and lava rock/ember material should be removed and the burner compartment vacuumed and wiped out. Remove and refit the logs as per the instructions in this manual. Always handle the logs with care as they are fragile and may also be hot if the fireplace has been in use.
  • Page 32: Replacement Parts

    33LDVR CFM Specialty Home Products reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. 33/36/39/43LDVR 36LDVR 18a,b 7317 LDVR parts 1/05 39LDVR 43LDVR 7a,b 6a,b 19a,b 10007317...
  • Page 33 Clamp Frame Window Top Louvre Assy Bottom Louvre Assy 33a. Support Rear Log 33b. Support Rear Log - LP Support Front Log ON/OFF Switch Ceramic Refractory Lining Kit (Optional) 10007317 33LDVR 36LDVR 10007567 10007318 10008214 B136 B137 B138 B135 10001454 10001454...
  • Page 34 Ignition Control from Synetek (EN) Wire Harness (EN) Synetek (low voltage) Wire Harness (EN) Synetek (high voltage) 10008140 Clevis Pin Clip Pin Hitch Fuel Conversion Kits Conversion Kit, NG to LP 33LDVR Kit # 10008233 36LDVR Kit # 10008235 39LDVR Kit # 10008237 43LDVR...
  • Page 35: Fan Kits

    Optional Accessories Available Fan Kits FK24 Fan Assembly This auxiliary fan system increases the efficiency of the circulation of the heated air. The FK24 fan kit allows variable speed control of the circulation fan and also incorporates a heat sensor in the circuit.
  • Page 36: Ceramic Refractory Lining

    Fig. 55 FK24 fan wiring. FP394 Ceramic Refractory Kits WIRING DIAGRAM 11/20/96 Ceramic refractory panels are available in kit form for the LDV series appliances Appliance Model Kit Name 33LDVR 33LDVRCR 36LDVR 36LDVCR 39LDVR 39LDVCR 43LDVR 43LDVCR Take care when handling the refractory panels as they are fragile until held in place and supported.
  • Page 37: Trim Kits

    Optional Trim Kits Louvre Accent Trim Appliance Model Main Louvre Kit Polished Brass 33LDVR 33DVLMP 36LDVR 36DVLMP 39LDVR 39DVLMP 43LDVR 43DVLMP Antique Brass 33LDVR 33DVLMA 36LDVR 36DVLMA 39LDVR 39DVLMA 43LDVR 43DVLMA Rustic Bronze 33LDVR 33DVLMR 36LDVR 36DVLMR 39LDVR 39DVLMR 43LDVR...
  • Page 38 LDVR Series Direct Vent Gas Fireplace 10007317...
  • Page 39: Warranty

    PRODUCT COVERED BY THIS WARRANTY All Vermont Castings gas stoves, gas inserts, and gas fireplaces, and all Majestic or Northern Flame brand gas fireplaces equipped with an Insta-Flame Ceramic Burner, or standard steel tube burner. BASIC WARRANTY CFM Specialty Home Products (hereinafter referred to collectively as the Company) warrants that your new Vermont Castings or Majestic Gas Fireplace/Stove is free from manufacturing and material defects for a period of one year from the date of purchase, subject to the...
  • Page 40: Energuide

    Efficiency Ratings Model EnerGuide Ratings Fireplace Efficiency (%) 33LDVRRN 62.6 33LDVRRP 62.6 33LDVREN 72.7 33LDVREP 72.7 36LDVRRN 57.5 36LDVRRP 57.5 36LDVREN 63.6 36LDVREP 63.6 39LDVRRN 50.2 39LDVRRP 50.2 39LDVREN 54.2 39LDVREP 54.2 43LDVRRN 54.3 43LDVRRP 54.3 43LDVREN 58.3 43LDVREP 58.3 CFM Specialty Home Products 410 Admiral Blvd.