OPERATING FIREPLACE
Continued
Figure 26 - Pilot
TO TURN OFF GAS
TO APPLIANCE
1. Turn off all electric power to the appliance
if service is to be performed.
2. Remove control access panel.
3. Close the gas valve.
CLEANING AND
MAINTENANCE
WARNING: Installation and
repair should be done by a quali-
fied service person. The appli-
ance should be inspected before
each use and at least annually
by a qualified service person.
More frequent cleaning may be
required due to excessive lint
from carpeting, bedding mate-
rial, pet hair, etc. It is imperative
that the control compartments,
burners and circulating air sys-
tem be kept clean.
WARNING: The logs can be
hot. Handle only when cool.
55173-G
electrical power before servicing
appliance. Any safety screen
or guard removed for servicing
must be replaced prior to operat-
ing the appliance.
WARNING: Failure to keep
the primary air opening(s) of
the burner(s) clean may result in
sooting and property damage.
Keep control compartment, logs, burner and area
surrounding logs clean by vacuuming or brushing
at least twice a year. Take care not to alter the set-
tings on the pilot assembly.
Do not use abrasive liquids or cleaners for cleaning
glass doors and trims. Any household glass cleaner
should suffice. Do not clean doors when hot. Allow
appliance to cool before cleaning.

TECHNICAL SERVICE

You may have further questions about installation,
operation or troubleshooting. If so, contact DESA's
Technical Service Department at 1-866-672-6040.
When calling please have your model and serial
numbers of your heater ready.
You can also visit DESA's Technical Services web
site at www.desatech.com.
GL36ST, GL36STE
• Maximum Input Rating at Altitudes: 2,000 ft.
- 42,000 Btu/hr., 2,000 ft. to 4,000 ft. - 37,800
Btu/hr.
• Manifold Pressure: 3.5 W.C. (.87 kPa)
• Supply Pressure (in. of water): Minimum* - 4.5"
(1.12 kPa), Maximum - 11.0" (2.74 kPa)
• Orifice Size at Altitudes: 2,000 ft. - #30, 2,000 ft.
to 4,000 ft. - #31
GL36STP, GL36STEP
• Maximum Input Rating at Altitudes: 2,000 ft.
- 42,000 Btu/hr., 2,000 ft. to 4,000 ft. - 37,800
Btu/hr.
• Manifold Pressure: 11.0 W.C. (2.74 kPa)
• Supply Pressure (in. of water): Minimum* -
12.0" (2.89 kPa), Maximum - 13.0" (3.23 kPa)
• Orifice Size at Altitudes: 2,000 ft. - #49, 2,000 ft.
to 4,000 ft. - #51
* For the purpose of input adjustment
www.desatech.com
WARNING: Turn off gas and

SPECIFICATIONS

15