38GJt
Multi-zone Ductless Split System
Sizes 18 t o 24
Owner' s Manual & Installation Instructions
NOTE: Read the entire instruction manual before starting the
installation.
Please read this Owner's Information Manual carefully before installing and using this appliance
and keep this manual for future reference.
For your convenience, please record the model and serial numbers of your new equipment in the
spaces provided. This information, along with the installation data and dealer contact information,
will be helpful should your system require maintenance or service.
UNIT INFORMATION
Model #
Serial #
INSTALLATION INFORMATION
Date Installed
the environmentally sound refrigerant
NOTE TO EQUIPMENT OWNER:
DEALERSHIP CONTACT INFORMATION
Company Name:
Address:
Phone Number:
Technician Name:

TABLE OF CONTENTS

SAFETY CONSIDERATIONS................................................1
NAME OF PARTS...............................................................3
TECHNICAL DATA..............................................................4
ELECTRICAL CONNECTIONS...............................................5
OUTDOOR UNIT INSTALLATION..........................................6
SYSTEM VACUUM.............................................................6
MAINTENANCE.......................................................................7
CLEARANCES...........................................................................7
OIL TRAP DESIGN REQUIREMENTS......................................8
TROUBLESHOOTING........................................................1 0
PAGE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 38GJ and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Carrier 38GJ

  • Page 1: Table Of Contents

    38GJt Multi-zone Ductless Split System Sizes 18 t o 24 Owner' s Manual & Installation Instructions TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS..........1 NAME OF PARTS...............3 TECHNICAL DATA..............4 OUTDOOR UNIT WORKING TEMPERATURE RANGE..4 ELECTRICAL CONNECTIONS..........5 OUTDOOR UNIT INSTALLATION..........6 SYSTEM VACUUM.............6 MAINTENANCE...............7 CLEARANCES................7 OIL TRAP DESIGN REQUIREMENTS........8 TROUBLESHOOTING............1 0...
  • Page 2: Safety Considerations

    CAUTION SAFETY CONSIDERATIONS Installing, starting up, and servicing air- -conditioning equipment can be hazardous due to system pressures, electrical components, EQUIPMENT DAMAGE HAZARD and equipment location (roofs, elevated structures, etc.). Failure to follow this caution may result in equipment Only trained, qualified installers and service mechanics should damage or improper operation.
  • Page 3 SAFETY CONSIDERATIONS GENERAL INFORMATION WARNING If the appliance emits smoke The air conditioner automatically If damage to the power or control turns on or off, according to your or a burning smell, wiring occurs, contact a settings. Do not turn on or turn immediately disconnect the professional to repair the wiring.
  • Page 4: Name Of Parts

    NAME OF PARTS GENERAL INFORMATION 38GJQC18---3: WARNING Turn off the power supply before cleaning the air conditioner to prevent electric shock. Volatile liquids such as thinner or gasoline will cause damage to the appearance of the air conditioner. (Only use a soft dry cloth or moist cloth to clean the air conditioner cabinet.) This product must not be disposed together with the domestic waste.
  • Page 5: Technical Data

    TECHNICAL DATA GENERAL INFORMATION MODE 38GJQD18---3 Electrical data Electricity supply 208/230V,60HZ Fuse or air switch 2.69 (2.5) mm ) Minimum power cord section ft ( Size and clearance 2.9(0.89) 1.19(0.362) 2.3(0.7) TECHNICAL DATA GENERAL INFORMATION 38GJQD24---3 MODE Electrical data Electricity supply 208/230V,60HZ Fuse or air switch mm )
  • Page 6: Electrical Connections

    ELECTRICAL CONNECTIONS INSTALLER 38GJQD18---3、38GJQD24---3 38GJQD18---3 1. Remove the handle at the right side plate of the outdoor unit (one screw). 2. Remove the wire clamp, connect the power connection wire with the terminal at the row of connection and secure the connection.
  • Page 7: Outdoor Unit Installation

    OUTDOOR UNIT INSTALLATION INSTALLER Location Install the drain fitting and the drain hose (for model with heat pump only) Use bolts to secure the unit to a flat, solid floor. Condensation is produced and flows from the out- When mounting the unit on a wall or the roof, ensure door unit when the appliance is operating in the sure the support is firmly secured so that it cannot heating mode.
  • Page 8: Maintenance

    MAINTENANCE INSTALLER Use suitable instruments for the refrigerant R410A. Only use refrigerant R410A. Do not use mineral oils to clean the unit. CLEARANCES INSTALLER The installation must be done by trained and qualified service personnel with the assistance of this manual.
  • Page 9: Oil Trap Design Requirements

    OIL TRAP DESIGN REQUIREMENTS INSTALLER If the height difference between the indoor unit and the outdoor unit exceeds 19.7ft (6m), install an oil trap every 19.7ft (6m) from the lower to the upper section of the vertical gas pipe. Fabricate the oil trap into two U-type elbows or one return-type elbow.
  • Page 10 OIL TRAP DESIGN REQUIREMENTS INSTALLER The outdoor unit is higher than the indoor unit. Stop elbow Outdoor unit Gas pipe 19.7ft (6m) Liquid pipe 19.7ft (6m) 19.7ft (6m) Oil trap 19.7ft (6m) 19.7ft (6m) Oil return trap Indoor unit...
  • Page 11: Troubleshooting

    TROUBLESHOOTING Check Items Problems From Improper Installation Is the installation reliable? The unit may drop, vibrate or make noises May cause unsatisfactory cooling (heating) Has the gas leakage been checked? effect Is the thermal insulation of the unit May cause condensation and water dripping sufficient? Is the drainage smooth? May cause condensation and water dropping...
  • Page 12 Copyright 2014 Carrier Corporation S 7310 W. Morris St. S Indianapolis, IN 46231 Edition Date: Catalog No: 38 Replaces: New Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.