CAC / BDP KSACN0101CAC Installation Instructions Manual

Wired controller for ductless split systems

Advertisement

Quick Links

KSACN0101CAC
KSACN0101AAA
Read and become familiar with these instructions before beginning
installation.
SAFETY CONSIDERATIONS
Read these instructions thoroughly and follow all warnings or
cautions included in the literature and attached to the unit.
Consult local building codes and National Electrical Code (NEC)
for special requirements. Recognize safety information.
This is the safety- alert symbol
the unit and in instructions or manuals, be alert to the potential for
personal injury. Understand these signal words: DANGER,
WARNING, and CAUTION. These words are used with the
safety- alert symbol. DANGER identifies the most serious hazards
which will result in severe personal injury or death. WARNING
signifies hazards which could result in personal injury or death.
CAUTION is used to identify unsafe practices which may result
in minor personal injury or product and property damage. NOTE
is used to highlight suggestions which will result in enhanced
installation, reliability, or operation.
WARNING
!
ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury or
death.
Before beginning any modification or installation of this kit, be
sure the main electrical disconnect is in the OFF position.
Ensure power is disconnected to the fan coil unit. On some
systems both the fan coil and the outdoor unit may be on the
same disconnect. Tag the disconnect switch with a suitable
warning label. There may be more than one disconnect.
CAUTION
!
EQUIPMENT DAMAGE HAZARD
Failure to follow this warning may result in equipment
damage.
Do not install the wired controller in an area subjected to
excessive steam, oil or sulfide gas. Doing so may cause the
controller to deform and/or fail.
WARNING
!
INSTALLATION
Entrust the distributor or authorized professionals to install the
unit. Installation by unskilled persons may lead to improper
installation, electric shock, or fire. Re- installation must be
performed by authorized professionals. Non- compliance may
lead to electric shock or fire.
Installation Instructions
! !
. When you see this symbol on
for Ductless Split Systems
Kit Contents: Confirm the following parts are included
No.
Description
1
Wired controller
Installation and Owner's
2
Manual
3
Screws
4
Wall plugs
Screws
5
6
Plastic screw bars
The connective wires
7
group
Field Supplied Components: Prepare the following assemblies
on site
Description
No.
Switch Box
1
Wiring Tube
2
(insulating sleeve and
tightening screw)
TABLE OF CONTENTS
SAFETY CONSIDERATIONS
INSTALLATION ACCESSORY
INSTALLATION METHOD
Wired Controller
Qty
Remarks
1
n/a
1
n/a
M4X20 (For mount-
3
ing on the wall)
3
For wall mounting
2
M4X25 (For mount-
ing on switch box)
For fixing on switch
2
box
1
24AWG
Type
Remarks
Qty
1
n/a
n/a
1
n/a
n/a
. . . . . . . . . . . . . . . . . . . .
1
. . . . . . . . . . . . . . . . . . .
2
. . . . . . . . . . . . . . . . . . . . . .
2

Advertisement

loading

Summary of Contents for CAC / BDP KSACN0101CAC

  • Page 1 KSACN0101CAC Wired Controller KSACN0101AAA for Ductless Split Systems Installation Instructions Read and become familiar with these instructions before beginning installation. SAFETY CONSIDERATIONS Read these instructions thoroughly and follow all warnings or cautions included in the literature and attached to the unit.
  • Page 2: Installation Accessory

    INSTALLATION ACCESSORY Installation precautions for the wired remote controller S Do not install in a location near heavy oil, vapor or sulfurated gas otherwise, this product will deform which will lead to a system malfunction. S Do not install the unit in a location near flammable gas leaks. Once flammable gases leak and are left near the wired controller, a fire may occur.
  • Page 3 Fig. 2 - Wiring Principle Sketch Fig. 3 - Wiring figure S Connect the female joint of the wires group from the main board to the male joint of the connective wires group. S Connect the other side of the connective wires group with the male joint of the wires group leads from the wired controller. S Remove the upper part of the wired controller.
  • Page 4 S Insert a slot screwdriver into the slots of the lower part of the wired controller (2 places), and remove the upper part of the wired controller. Fig. 4 - wired controller WARNING The PCB is mounted in the upper part of the wired controller.
  • Page 5 S For flush- mounting, fasten the back plate of the switch box with 2 screws (M4x25) and then fasten it to the wall with 1 screw (M4x20). Fig. 6 - Switch box NOTE: Place on a flat surface. Be careful not to distort the back plate of the wired controller by over tightening the mounting screws. Fig.
  • Page 6 S For exposed mounting there are four outlet positions and three require cutting. Fig. 8 - Outlet Fig. 9 - Wiring hole Fig. 10 - trap WARNING To keep water from entering the wired remote controller, use a trap and putty to seal the wire connectors during wiring installation.
  • Page 7 Fig. 11 - Upper case The pictures in this manual are for illustration purposes only. Your wired controller may differ slightly. Catalog No: KSACN0101- 01SI Copyright 2015 CAC / BDP S 7310 W. Morris St. S Indianapolis, IN 46231 Edition Date: 02/15 Replaces: NEW...

This manual is also suitable for:

Ksacn0101aaa