Taking Care Of The Guide Bar; Air Filter System - Stihl MS 250 Instruction Manual

Hide thumbs Also See for MS 250:
Table of Contents

Advertisement

Available languages

Available languages

Taking Care of the Guide Bar

2
1
Turn the guide bar over – every time
N
you sharpen the chain and every
time you replace the chain – this
helps avoid one-sided wear,
especially at the nose and
underside of the bar.
Regularly clean the oil inlet hole (1),
N
the oilway (2) and the bar groove
(3).
Measure the groove depth – with the
N
scale on the filing gauge (special
accessory) – in the area used most
for cutting.
MS 250
Chain
Chain pitch
type
Picco
1/4" P
Rapid
1/4"
Picco
3/8" P
Rapid
3/8"; 0.325"
Rapid
0.404"
If groove depth is less than specified:
Replace the guide bar.
N
The drive link tangs will otherwise
scrape along the bottom of the groove –
the cutters and tie straps will not ride on
the bar rails.
3
Minimum

Air Filter System

groove depth
0.16" (4.0 mm)
The air filter system can be adapted to
0.16" (4.0 mm)
suit different operating conditions by
0.20" (5.0 mm)
installing a choice of filters. Changing
0.24" (6.0 mm)
the filter is quick and simple.
0.28" (7.0 mm)
The saw comes standard with either a
fabric filter or a fleece filter.
Fabric filter
For normal operating conditions and
winter operation.
Fleece filter
For dry and very dusty work areas.