(7) Adjust voltage applied to pins 3 and 4 to obtain readings within limits for pointer
Test Point % provided in Figure 202.
(8) Connect digital voltmeter at receptacle 9811−J104 pins E and F (engine No. 1) or
pins G and H (engine No. 2) and repeat step (7) to obtain digital readings for
indicator and voltage output to Flight Data Recorder (FDR) within limits of Figure
202.
(9) Disconnect power supplies. Reconnect connectors 7700−P1 at ECU, 7700−P7 at
SCU and 9811−P104 at relay panel at station X210 in cabin. Close circuit breakers
opened in steps (2) and (3).
MASTER
EFFECTIVITY: See Pageblock 77−10−11 page 201
D
S ERIES 100
AIRCRAFT MAINTENANCE MANUAL
77−10−11
Dec 20/2004
Page 202