CASTILE-B PELLET STOVE
Model(s):
CASTILE-MBK-B
CASTILE-CWL-B
CASTILE-CSB-B
CASTILE-PMH-B
CAUTION
Tested and approved for wood pellets or shelled corn only.
Burning of any other type of fuel voids your warranty.
CAUTION
Check building codes prior to installation.
• Installation MUST comply with local, regional, state and na-
tional codes and regulations.
• Consult local building, fi re offi cials or authorities having juris-
diction about restrictions, installation inspection, and permits.
1
Installation Manual
Installation & Appliance Set-Up
NOTICE: DO NOT DISCARD THIS MANUAL
Tested and
Portland
O-T L
Listed by
Oregon USA
C
US
OMNI-Test Laboratories, Inc.
If the information in these instruc-
tions is not followed exactly, a
fi re could result causing property
damage, personal injury, or death.
• Do not store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of
this or any other appliance.
• Do not overfi re - If heater or chimney con-
nector glows, you are overfi ring. Overfi ring
will void your warranty.
• Comply with all minimum clearances to
combustibles as specifi ed. Failure to
comply may cause house fi re.
Hot glass will cause burns.
Do not touch glass until it is cooled
NEVER allow children to touch glass
Keep children away
CAREFULLY SUPERVISE children in same room as
fi replace.
Alert children and adults to hazards of high temperatures
High temperatures may ignite clothing or other
fl ammable materials.
Keep clothing, furniture, draperies and other fl ammable
materials away.
To obtain a French translation of this manual, please contact
your dealer or visit www.quadrafi re.com
Pour obtenir une traduction française de ce manuel, s'il vous
plaît contacter votre revendeur ou visitez www.quadrafi re.com
7021-154A
WARNING
WARNING
HOT SURFACES!
Glass and other surfaces are hot
during operation AND cool down.
NOTE
7/9/2014

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CASTILE-MBK-B and is the answer not in the manual?

Questions and answers

Summary of Contents for Hearth & Home CASTILE-MBK-B

  • Page 1 fi re could result causing property Model(s): damage, personal injury, or death. CASTILE-MBK-B • Do not store or use gasoline or other fl am- CASTILE-CWL-B mable vapors and liquids in the vicinity of this or any other appliance.
  • Page 2: Table Of Contents

    CASTILE FREESTANDING Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury. • WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury. • CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
  • Page 3: Important Safety Information

    CASTILE FREESTANDING Important Safety Information A. Appliance Certifi cation D. Electrical Rating 115 VAC, 60 Hz, Start 4.1 Amps, Run 1.1 Amps Model Castile Pellet Stove Laboratory OMNI Test Laboratories, Inc. E. Mobile Home Approved Report No. 061-S-77d-6.2 • This appliance is approved for mobile home installa- Type Solid Fuel Room Heater/Pellet Fuel tions when not installed in a sleeping room and when...
  • Page 4: Getting Started

    CASTILE FREESTANDING Install Guide Getting Started A. Design, Installation & Location Considerations Since pellet exhaust can contain ash, soot or sparks, you must consider the location of: 1. Appliance Location • Windows NOTICE: Check building codes prior to installation. • Air Intakes •...
  • Page 5: Thermostat Wall Control Location

    CASTILE FREESTANDING B. Thermostat Wall Control Location WARNING The thermostat wall control’s location will have some affect on the appliance’s operation. Fire Risk. • Maximum wire length from appliance is 100 feet (30.48m) Damaged parts could impair safe operation. continuous unspliced wire. Recommended 20 gauge wire, Do NOT install damaged, incomplete or solid copper substitute components.
  • Page 6: Install Checklist

    Location of Fireplace: Installer: Dealer/ Distributor Phone #: Serial #: Model (circle one): CASTILE-MBK-B CASTILE-CWL-B CASTILE-CSB-B CASTILE-PMH-B WARNING! Risk of Fire or Explosion! Failure to install fi replace according to these instructions can lead to a fi re or explosion.
  • Page 7: Dimensions And Clearances

    CASTILE FREESTANDING Dimensions and Clearances A. Appliance Dimensions 24 in. (609mm) 12 in. (305mm) 28-9/16 in. (725mm) 24-5/8 in. (626mm) 24 in. (609mm) Figure 7.1 - Top View Figure 7.2- Front View 27-7/8 in. (708mm) 5 in. 22-7/8 in. (126mm) 3 in.
  • Page 8: Clearances To Combustibles (Ul And Ulc)

    CASTILE FREESTANDING B. Clearances to Combustibles (UL and ULC) Alcove Installation Inches Millimeters Minimum Alcove Height 1092 Minimum Alcove Side Wall Minimum Alcove Width Maximum Alcove Depth C. Hearth Pad Requirements (UL and ULC) Use a non-combustible fl oor protector, extending beneath appliance and to the front, sides and rear as indicated.
  • Page 9: Vent Information

    CASTILE FREESTANDING Vent Information A. Venting Termination Minimum Requirements Electrical Service Inside Corner FIXED FIXED OPEN CLOSED CLOSED OPEN J or K Figure 9.1 Termination Cap Air Supply Inlet Restricted Area Gas Meter All minimum clearances are listed with an Outside Air Kit (OAK) installed, unless otherwise noted in table below. 12 in.
  • Page 10: Avoiding Smoke And Odors

    CASTILE FREESTANDING B. Avoiding Smoke and Odors • Maintain specifi ed clearances to windows, doors and air inlets, including air conditioners. Negative Pressure, Shut-Down and Electrical Power Failure • Vents should not be placed below ventilated soffi ts. To reduce the probability of back-drafting or burn-back in Run the vent above the roof.
  • Page 11: Draft

    CASTILE FREESTANDING To minimize the effects of negative air pressure: 6. DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENT- ING SYSTEM OF THIS UNIT. • Install the outside air kit with the intake facing prevailing winds during the heating season 7.
  • Page 12: Equivalent Feet Of Pipe

    CASTILE FREESTANDING G. Equivalent Feet of Pipe WARNING The table below can help you calculate the equivalent feet Vent surfaces get HOT, can cause burns if of pipe which is a method used to determine pellet vent size. touched. Non-combustible shielding or guards Figure 12.1.
  • Page 13: Pellet Venting Charts

    CASTILE FREESTANDING I. Pellet Venting Charts WARNING The maximum horizontal venting allowed with no vertical vent- ing attached is 48 inches (1219mm) including one 90° elbow Fire Risk. or two 45° elbows. This is our recommended horizontal vent- • Only LISTED venting components may be used. ing installation.
  • Page 14: Venting Systems

    CASTILE FREESTANDING Venting Systems A. Alcove Figure 14.1 Minimum* Maximum Inches Millimeters Inches Millimeters Height 1092 Width Depth To Side Wall *All minimums listed are to a combustible surface. NOTE: • Illustrations refl ect typical installations and are FOR DESIGN PURPOSES ONLY. •...
  • Page 15: Through The Wall

    CASTILE FREESTANDING B. Through The Wall NOTE: In Canada, where passage through a wall or partition of com- Horizontal termination cap must be a minimum of 6 inches. bustible construction is desired, the installation shall conform to (152mm) from the wall. Approved for mobile home installa- CAN/CSA-B365 tions.
  • Page 16: Vertical Into Existing Class A Chimney

    CASTILE FREESTANDING C. Vertical into Existing Class A Chimney We recommend a minimum of 60 inches (1524mm) vertical, however above the eave is preferred. All three installations are approved for mobile Rain Cap home installations. Must use 3 or 4 inch (76 to 102mm) “L”...
  • Page 17: Masonry

    CASTILE FREESTANDING WARNING Fire Risk Inspection of Chimney: • Masonry chimney must be in good condition. • Meets minimum standard of NFPA 211 • Factory-built chimney must be a minimum 6 inch (152mm) UL103 HT. F. Masonry Fireclay flue Concrete Cap liner with airspace Flashing 1 in.
  • Page 18: Appliance Set-Up

    CASTILE FREESTANDING Appliance Set-Up A. Outside Air Kit Instructions CAUTION Parts Included in Kit: 1 piece of 2 inch x 3 foot fl ex hose, 2 hose clamps, 1 collar assembly,1 termination cap assembly, Never draw outside combustion air from: 1 trim ring, 12 screws.
  • Page 19: Top Vent Adapter Installation

    CASTILE FREESTANDING B. Top Vent Adapter Installation C. Rear Vent & Rear Vent to Top Vent Adapter 3 to 3 inch Top Vent Adapter Installation 3 to 6 inch Top Vent Offset Adapter Put a layer of high temperature silicone on the 3 inch (76mm) exhaust outlet.
  • Page 20: Optional Log Set Placement Instructions

    CASTILE FREESTANDING E. Optional Log Set Placement Instructions F. Thermostat Installation A 12 volt AC thermostat is required to operate this pellet 2 Piece Log Set Installation appliance. You may use the included wall mount thermo- Open door to expose the fi rebox. stat or purchase an optional programmable thermostat Install the left log fi...
  • Page 21: Mobile Home Installation

    CASTILE FREESTANDING Mobile Home Installation You must use a Quadra-Fire Outside Air Kit CAUTION for installation in a mobile home. THE STRUCTURAL INTEGRITY OF THE MOBILE HOME An outside air inlet must be provided for the combustion air and FLOOR, WALL AND CEILING/ROOF MUST BE MAINTAINED must remain clear of leaves, debris, ice and/or snow.
  • Page 22: Accessory List

    CASTILE FREESTANDING Accessory List Castile-FS-B Service Parts Beginning Manufacturing Date: Oct. 2009 Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION . Parts must be ordered from a dealer or Stocked Hearth and Home Technologies does not sell directly to consumers distributor.
  • Page 23 CASTILE FREESTANDING 7/9/2104 7021-154A...
  • Page 24 CONTACT INFORMATION Hearth & Home Technologies 1445 North Highway Colville, WA 99114 Division of HNI INDUSTRIES Please contact your Quadra-Fire dealer with any questions or concerns. For the number of your nearest Quadra-Fire dealer log onto www.quadrafi re.com CAUTION DO NOT DISCARD THIS MANUAL Read, understand and Leave this manual with •...