Care And Maintenance - EmberGlow VFF26NLM Owner's Operation And Installation Manualmanual

Vent-free gas compact fireplace
Table of Contents

Advertisement

Available languages

Available languages

Figure 22 - Correct Pilot Flame Pattern
(Natural Gas shown)
Figure 24 shows a correct burner flame pattern. Figure 25 shows an incorrect burner flame
pattern. If burner flame pattern is incorrect then:
• turn heater off (see To Turn Off Gas to Appliance, page 19).
• see Troubleshooting pages 22 through 24.
Approx. 3"-6" Above Top of Logs
Figure 24 - Correct Burner Flame Pattern
with Control Knob Set to HI (5)
More Than 8" Above Top of Logs
Air is drawn into the burner through the holes in the fitting at the entrance to the burner. These
holes may become blocked with dust or lint. Periodically inspect these holes for any blockage
and clean as necessary. Blocked air holes will create soot.
WARNING: Turn off heater and let cool before servicing.
CAUTION: You must keep control areas, burner, and circulating
air passageways of heater clean. Inspect these areas of heater before
each use. Have heater inspected yearly by a qualified service techni-
cian. Heater may need more frequent cleaning due to excessive lint
from carpeting, bedding material, pet hair, etc.
WARNING: Failure to keep the primary air opening(s) of the
burner(s) clean may result in sooting and property damage.
Periodically inspect all burner flame holes with
the heater running. All slotted burner flame
holes should be open with yellow flame pres-
ent. All round burner flame holes should be
open with a small blue flame present. Some
20
INSPECTING BURNERS
BURNER FLAME PATTERN
BURNER PRIMARY AIR HOLES

CARE AND MAINTENANCE

MAIN BURNER
www.sureheat.com
Approx. 3"-6" Above Top of Logs
Figure 23 - Incorrect Pilot Flame Pattern
(Natural Gas shown)
More Than 8" Above Top of Logs
Figure 25 - Incorrect Burner Flame
Pattern with Control Knob Set to HI (5)
burner flame holes may become blocked by
debris or rust, with no flame present. If so,
turn off the heater and let it cool, and remove
blockage or replace burner. Blocked burner
flame holes will create soot.
200084-01A