6.6.1.1 When TA<13℃, the compressor stops working. And the outdoor fan will stop delaying for 5
seconds until it operates for 3minutest.
6.6.1.2 When TA≥15℃, the outdoor fan operates, and the compressor will restart to operate after
15seconds.
6.6.2. The speed can't be controlled at drying mode, and the indoor fan motor operates at low speed.
6.6.3 Power management (for power management models)
Entering into drying mode, indoor fan motor operates immediately and keeps moving for 30 minutes
at lease. Compressor operates, and indoor fan motor keeps moving; Compressor stops operation,
indoor fan motor shuts off after a delay of 30 minutes.
6.6.4. The ION/TIMER functions are valid at the drying mode.