WARNING:
Service should not be attempted by anyone unfamiliar with the necessary precautions for this recording or playback
equipment. The following precautions are necessary during servicing:
1.
Many electrical and mechanical parts in this recorder have
special safety-related characteristics for providing protec-
tion against shock, fire and other hazards. These charac-
teristics often go unnoticed in a visual inspection, and the
protection afforded by them cannot necessarily be ob-
tained by using replacement components with higher rat-
ings (voltage, wattage, etc.).
2.
Replacement parts having special safety-related charac-
teristics are identified in this manual, and in the schematic
diagrams, by the symbol ! . These components have
values that are of special significance to product safety.
Should any component (identified by the symbol
to be replaced, use only the part designated in the parts
List. Do not deviate from the specified resistance, wattage,
and voltage ratings.
Digital Video
Recorder

SAFETY PRECAUTIONS

3. Before returning the set to the customer, always perform an
) need
4. Fuse symbol marks.
− 2 −
AC leakage current check on the exposed metallic parts of
the cabinet, such as terminals, screwheads, metal over-
lays, etc. to be sure that the set is safe to operate without
the danger of electrical shock, Plug the AC line cord directly
into a 120 V AC outlet. (Do not use a line isolation trans-
former during this check.) Use an AC voltmeter with a
sensitivity of 5000 ohms per volt (or more) as follows:
Connect a 1500 ohms, 10 watt resistor, paralleled by a 0.15
mfd, 150 VAC capacitor, between a known good earth
ground (water pipe, conduit, etc.) and the exposed metallic
parts, one at a time. Measure the AC voltage across the
1500 ohms resistor and 0.15 mfd capacitor combination.
Reverse the AC plug at the AC outlet and repeat the AC
voltage measurements for each exposed metallic part. The
measured voltage must not exceed 300 mVrms. This
corresponds to 200 µA AC. Any value exceeding this limit
constitutes a potential shock hazard and must be corrected
immediately.
For CANADA
For U.S.A.
UNDERWRITERS LABORATORIES Standard
CAUTION
"Risk of fire-replace fuse as marked"
Fuse rating is marked at
adjacent fuse.