Troubleshooting; Error Codes And Description - Daikin FTXS35K2V1B Service Manual

Inverter pair wall mounted type k-series
Hide thumbs Also See for FTXS35K2V1B:
Table of Contents

Advertisement

Troubleshooting

4. Troubleshooting

4.1

Error Codes and Description

System
Indoor
Unit
Outdoor
Unit
57
Error Codes
00
Normal
U0
Refrigerant shortage
U2
Low-voltage detection or over-voltage detection
U4
Signal transmission error (between indoor unit and outdoor unit)
UA
Unspecified voltage (between indoor unit and outdoor unit)
A1
Indoor unit PCB abnormality
A5
Freeze-up protection control / heating peak-cut control
A6
Fan motor (DC motor) or related abnormality
C4
Indoor heat exchanger thermistor or related abnormality
C9
Room temperature thermistor or related abnormality
E1
Outdoor unit PCB abnormality
E5
OL activation (compressor overload)
E6
Compressor lock
E7
DC fan lock
E8
Input overcurrent detection
EA
Four way valve abnormality
F3
Discharge pipe temperature control
F6
High pressure control in cooling
H0
Compressor system sensor abnormality
H6
Position sensor abnormality
H8
DC voltage / current sensor abnormality (35/42 class only)
H9
Outdoor temperature thermistor or related abnormality
J3
Discharge pipe thermistor or related abnormality
J6
Outdoor heat exchanger thermistor or related abnormality
L3
Electrical box temperature rise
L4
Radiation fin temperature rise
L5
Output overcurrent detection
P4
Radiation fin thermistor or related abnormality
: Displayed only when system-down occurs.
Description
SiBE041213E
Reference
Page
63
65
67
69
58
59
60
62
62
70
72
74
75
76
77
79
80
81
82
84
85
85
85
87
88
90
85